SM SYGNUS SHC USER´S MANUAL
15
SU Installation window
• Go to the installation window and configure the SU’s desired management IP (for example:
10.40.40.253).
• Configure the primary MU ID (same MU ID that was configured at the MU’s link configuration
window).
• Configure the channels you want the SU to scan. You can leave all channels marked to scan the
entire band or select the exact channel configured at the MU.
• Press “Submit” to save the changes.
Checking the Setup
Make sure to provide some distance between the units to avoid transmission saturation. Align
the antennas in a way that keeps the RSSI level below
–50 dBm
From the MU PC issue the command ping x.x.x.x
–t, where x.x.x.x is the IP of the PC behind
the SU. Make sure both PCs are on the same subnet, for example: 10.1.1.10/24 and
10.1.1.20/24.
Typical outdoor installation scheme:
1.
Sygnus SHC - Outdoor Unit with integrated Antenna
2.
Outdoor to Indoor CAT5
3.
Indoor Outlet
4.
User computer
5.
Indoor CAT5
6.
Power
7.
Supply
8.
100-240V
9.
AC