4
Available DIP switch settings (Parallel Interface)
The following table shows all the possible settings for the DIP switch. The
factory default settings are ON for switches 1 through 7 and OFF for switch 8.
A reset can be performed with pin 31 on the interface by setting DIP switch 1 to
ON (the factory default setting).
In addition, when a reset can be performed with pin 31, setting DIP switch 2 to
OFF sets up the unit to perform a reset when pin 31 and pin 36 are “LOW”.
*1: Never set switch 7 to OFF at the same time that switch 8 is set to ON.
Switch
Parameter
ON
OFF
1
Pin 31 / Pin 36 Reset Signal
See table below.
2
3
Not used
(Always ON)
4
5
6
7
Command Emulation
See table below.
8
Reset Signal
Switch 1
Switch 2
Pin 31 is enabled.
ON
ON
Pin 31/Pin 36 are enabled.
ON
OFF
Disabled
OFF
ON
Disabled
OFF
OFF
Command Emulation
Switch 7
Switch 8
Star mode
ON
ON
ESC/POS (TM-295)
ON
OFF
ESC/POS (TM-290)
OFF
OFF
Not used (*1)
OFF
ON
Содержание SLIP SP298 SERIES
Страница 1: ...SLIP PRINTER SP298 SERIES Programmer s Manual...
Страница 66: ...63 Star Mode Character table Normal...
Страница 67: ...64 Star Mode Character table katakana Note Other characters are the same as those for Character table Normal...
Страница 71: ...68 Star Mode International Character Set...
Страница 72: ...69 ESC POS Mode Page 0 PC437...
Страница 73: ...70 ESC POS Mode Page 0 PC437...
Страница 74: ...71 ESC POS Mode Page 1 Katakana Note Other characters are the same as those for Page 0...
Страница 75: ...72 ESC POS Mode Page 2 PC858 Multilingual Note Other characters are the same as those for Page 0...
Страница 76: ...73 ESC POS Mode International Character Set...
Страница 77: ......
Страница 78: ...Blank Page...