background image

13

PARTS LIST

EFFECTIVE

 

IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED

            PAGE

          INCLUDE MODEL AND SERIAL NUMBER

               

OF

Some items are included for illustrative purposes only and in certain instances may not be available.

 

  

Number

Per

Unit

Description and Model Designation

MODEL

Part

Number

Key

Number

   

 

   

3/28/03   Rev. B

1

2R-Z1273

2

KNOB-CONTROL

2

G3-Z1315

1

FRONT  PANEL

3

2A-Z0314

4

LEG

4

G3-624164

1

GRIDDLE PLATE ASSEMBLY

624TA

G3-GD0001

1

GRIDDLE PLATE ASSEMBLY

624TB

5

G3-Y7046

1

GREASE DRAWER GRIDDLE

6

G3-Y7047

2

SLIDE DRAWER

7

2F-Y7052

2

BURNER ASSEMBLY

8

G3-624233

1

MANIFOLD ASSEMBLY COMPLETE

624TA

G3-GD0037

1

MANIFOLD ASSEMBLY COMPLETE

624TB

9

2P-1453

1

PLUG-PIPE

10

2V-6671

2

VALVE-PILOT

11

G3-T1022

2

TUBE ORIFICE

12

2J-Y7250

2

ORIFICE #55 L.P.

13

2A-9369

2

ORIFICE-FITTING

14

2K-Y7111

2

FITTING COMPRESSION

15

2T-Z4293

2

THERMOSTAT

16

2K-Y7123

1

INLET PIPE

17

G3-Y7252

1

INLET PIPE SUPPORT

18

G3-Y7355

2

TUBE-PILOT

19

G3-Y7356

2

PILOT BRACKET

20

G3-Z3785

1

REGULATOR-PRESSURE

21

G3-Y7040

1/2

TENSIONER

624TA

22

G3-Y7039

1/2

BULB-CLAMP

624TA

G3-Z4398

1/2

BULB-CLAMP

624TB

G3-GD0036

2

TUBE-WASHER ASSY. (NOT SHOWN)

624TB

1
1

8G-624TA-LP and 8G-624TB-LP STAR-MAX
GAS GRIDDLE 24" THERMOSTATIC CONTROL

   

   

Star Manufacturing International, Inc.

      23                  2M-Z1291                      1                  Faceplate                                                624TA, 624TB

07-03-06  RB

(2T-Y7590 = Stem)

Содержание 636TB-LP

Страница 1: ... 8G 648MA LP 8G 624TA LP 8G 636TA LP 8G 648TA LP 8G 624TB LP 8G 636TB LP 8G 648TB LP Star Manufacturing International Inc 10 Sunnen Drive St Louis MO 63143 Phone 314 781 2777 Fax 314 781 3636 Installation and Operating Instructions 2M Z3793 Rev B 3 28 03 636MA LP ...

Страница 2: ...mensions 48 W x 27 3 4 D x 13 1 2 H 121 9 cm W x 70 5 cm D x 34 3 cm H 8G 624TA LP 8G 624TB LP Type Thermostat Control 2 Controls 40 000 BTU 498 sq in 3213 4 sq cm Grid Area 3 4 1 9 cm Plate Thickness Approximate Weight Installed 165 lbs 74 8 kg Shipping 175 lbs 79 4 kg Dimensions 24 W x 27 3 4 D x 13 1 2 H 61 cm W x 70 5 cm D x 34 3 cm H 8G 636TA LP 8G 636TB LP Type Thermostat Control 3 Controls ...

Страница 3: ...tions and product design without notice Such revisions do not entitle the buyer to corre sponding changes improvements additions or replacements for previously purchased equipment MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance Refer to the authorized service center listing provided with the unit The Star Service Help Desk 1 800 807 9054 is a...

Страница 4: ...ingofthat system at test pressures in excess of 1 2 PSIG 3 45KPA This appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG 3 45KPA For your protection we recommend a qualified installingagencyinstallthisapplia...

Страница 5: ...rmostat will occur GAS PIPING Gas piping shall be of such size and so installed as to provide a supply of gas sufficient to meet the full gas inputoftheappliance Iftheapplianceistobeconnected to existing piping it shall be checked to determine if it has adequate capacity Joint compound pipe dope shall be used sparingly and only on the male threads of the pipe joints Such compounds shall be resista...

Страница 6: ...t 5 minutes to clear gas 2 Turn off all knobs and pilot valves and wait 5 minutes to clear gas 3 Turn on main valve and light all pilots 4 Turn burner knobs to desired setting 5 To turn burners off turn knobs off NOTE Thegriddlesareequippedwithstandingpilots andshouldbelitimmediatelyafterthegasisturnedon OVERNIGHTSHUTDOWN Turn knobs to the off position to turn burners off OPERATING INSTRUCTIONS SE...

Страница 7: ... Ifthere is an accumulation of burned on fat and food the griddle should be thoroughly scoured and reseasoned Use pumice or griddle stone while thegriddleiswarm Donotusesteelwoolbecause of the danger of steel slivers getting into the food 2 Daily use a clean cloth and good non abrasive cleaner to clean the stainless steel body of the griddle Wipe the polished front with a soft cloth 3 At least onc...

Страница 8: ...12 23 07 03 06 RB ...

Страница 9: ...NER ASSEMBLY 8 G3 624233 1 MANIFOLD ASSEMBLY COMPLETE 624TA G3 GD0037 1 MANIFOLD ASSEMBLY COMPLETE 624TB 9 2P 1453 1 PLUG PIPE 10 2V 6671 2 VALVE PILOT 11 G3 T1022 2 TUBE ORIFICE 12 2J Y7250 2 ORIFICE 55 L P 13 2A 9369 2 ORIFICE FITTING 14 2K Y7111 2 FITTING COMPRESSION 15 2T Z4293 2 THERMOSTAT 16 2K Y7123 1 INLET PIPE 17 G3 Y7252 1 INLET PIPE SUPPORT 18 G3 Y7355 2 TUBE PILOT 19 G3 Y7356 2 PILOT B...

Страница 10: ...LETE 648TA G3 GD0039 1 MANIFOLD ASSEMBLY COMPLETE 636TB G3 GD0040 1 MANIFOLD ASSEMBLY COMPLETE 648TB 9 2P 1453 1 PLUG PIPE 10 2V 6671 3 4 VALVE PILOT 636 648 11 G3 T1022 3 4 ORIFICE TUBE 636 648 12 2J Y7250 3 4 ORIFICE 55 L P 636 648 13 2A 9369 3 4 ORIFICE FITTING 636 648 14 2K Y7111 3 4 FITTING COMPRESSION 636 648 15 2T Z4293 3 4 THERMOSTAT 636 648 16 2K Y7123 1 INLET PIPE 17 G3 Y7252 1 INLET PIP...

Отзывы: