Stanton M.201 Скачать руководство пользователя страница 2

IMPORTANT TO SAFETY 

 

1.  Read these Instructions   
2.  Keep these Instructions 
3.  Heed all Warnings 
4.  Follow all Instructions   
5.  Do not use this apparatus near water 
6.  Clean only with dry cloth 
7. Do not block any ventilation openings. Install in 

accordance with the manufacturer’s instructions. 

8.  Do not install near any heat sources such as radiators, 

hear registers, stoves, or other apparatus (including 
amplifiers) that produce heat. 

9.  Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades with 
one wider than the other. A grounding type plug has two 
blades and a third grounding prong. The wide blade or the 
third prong are provided for your safety. If the provided plug 
does not fit into your outlet, consult an electrician for 
replacement of the obsolete outlet. 

10. Protect the power cord from being walked on or pinched 

particularly at plugs, convenience receptacles, and the 
point where they exit from the apparatus. 

11. Only use attachments/accessories specified by the 

manufacturer. 

12.  

Use only with the cart, stand, tripod, 
bracket, or table specified by the 
manufacturer, or sold with the apparatus. 
When a cart is used, use caution when 
moving the cart/apparatus combination to 
avoid injury from tip-over. 

13. Unplug this apparatus during lightning storms or when 

unused for long periods of time. 

14. Refer all servicing to qualified Stanton service center. 

Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or plug 
is damaged, liquid has been spilled or objects have 
fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, 
or has been dropped. 

15. This appliance shall not be exposed to dripping or 

splashing water and that no object filled with liquids 
such as vases shall be placed on apparatus. 

 

 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

CAUTION

 
CAUTION: To reduce the risk of electric shock, do not remove 
the cover (or back). No user-serviceable parts inside. Refer 
servicing to qualified service personnel. 
 

 

 

 
 

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the use to 
the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of 
sufficient magnitude to constitute a risk of electric shock to persons. 

 

 

 
 

The exclamation point within the equilateral triangle is intended to alert the user to the presence of 
important operating and maintenance (servicing) instructions in the literature accompanying the 
appliance. 

 

CAUTION 

 

To prevent electric shock, do not use this polarized plug with an extension cord, receptacle or other outlet unless 

the blades can be fully inserted to prevent blade exposure. 

 

 

 

 

 

 

Содержание M.201

Страница 1: ...S TANT O N MAG NE T IC S INC 1 954 689 8833 w w w s t a n t o n d j c o m information stantondj com...

Страница 2: ...ver 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified Stanton service center Servicing is required when the apparatus has bee...

Страница 3: ...LINE VOLTAGE SELECTION M 201 FEATURES 3 band EQ w input GAIN control per channel Power on off muting Long lasting crossfader M 201 CONTENTS 1 2 13 3 4 5 6 7 8 11 10 12 9...

Страница 4: ...ll output level 12 Level Indicators The dual LED indicators are used to indicate the master output level of channels Right and Left 13 Mic EQ The mic channel include a two band EQ with a range of 10dB...

Страница 5: ...plifier s and or audio receivers such as tape decks Plug your mixer into AC power Now you are ready to switch everything on IMPORTANT Always switch on your audio input sources such as turntables or CD...

Страница 6: ...INE LESS THAN 90dBV PHONO LESS THAN 80dBV MIC LESS THAN 50dBV THD N MASTER 0dBV OUTPUT MAXIMUM GAIN w 20kHz LPF LINE LESS THAN 0 05 20 20KHz PHONO LESS THAN 0 1 20 20KHz IEC A WTD MIC LESS THAN 0 2 20...

Страница 7: ...headshell 6 Operating instructions 7 RCA cables with ground wire 8 Target light 9 AC cord 10 Cloth dust cover Notes 1 Do not connect the AC power plug before assembly has been completed 2 Read this m...

Страница 8: ...ect the lead wires to the cartridge terminals The terminals of most cartridges are color coded Connect each lead wire to the terminal of the same color White L Left channel Blue L Left channel Red R R...

Страница 9: ...latter will start to rotate 6 Move the tonearm over the desired groove 7 When play is finished move the tonearm to the arm rest secure the tonearm with the arm clamp 8 Press the Start Stop button to s...

Страница 10: ...V 60Hz For U S A Canada Mexico AC 220V 50Hz For United Arab Emirates Chile Argentina AC 220V 60Hz For Philippines AC 230V 50Hz For Europe New Zealand South Africa Singapore Israel AC 240V 50Hz For Aus...

Страница 11: ...try where the purchaser is located or the country in which the merchandise was received Any returns to a non authorized dealer or to an authorized Stanton dealer not in the same country as the merchan...

Страница 12: ...Country Telephone Model Number Serial Number Date of Purchase Where did you buy this product If you have internet access please register your product at www stantondj com Otherwise return this card co...

Страница 13: ...PLACE STAMP HERE Stanton Magnetics Inc 3000 SW 42nd Street Hollywood FL 33312 U S A...

Отзывы: