3

Measuring

Stanley TLM 210  1.0.0 gb 

CLEAR Key

Pushing the 

CLEAR

 - key {

A, 5

} clears the last entry 

or measurement. Within a function (area, volume, 
etc.) single measurements can be deleted step by 
step and re-measured. 

Illumination

The display backlight remains on for 15 seconds after 
the last key press. 

Measuring Reference

The default reference setting is from the rear of the 
instrument. By pressing the 

REFERENCE

 - key {

A, 6

}, 

the setting can be changed, so that the next 
measurement taken will be from the "front" of the in-
strument. Afterwards the reference setting automat-
ically defaults back to rear. See picture {

D

}. By 

pressing 

REFERENCE

 - key {

A, 6

} long, the reference 

setting will stay from the "front" of the instrument. 
Repeated pressing of the 

REFERENCE

 - key {

A, 6

} will 

set the instrument to its default reference setting.

Measuring

Single Distance Measuring

Pressing 

ON/MEASURING

 - key {

A, 1

} turns the laser 

on. Aim at the desired target and press 

ON/MEASU-

RING

 - key {

A, 1

} again. The measured distance is 

displayed immediately in the chosen unit. 

Minimum/Maximum Measuring

This function allows the user to measure the 
minimum or maximum distance from a fixed 
measuring point as well as to determine spacing - see 
figure {

E

}. It is commonly used to measure a diagonal 

distance (maximum value) or a horizontal distance 
(minimum value). 
Press and hold 

ON/MEASURING

 - key {

A, 1

} until you 

hear a beep, indicating the device is in a continuous 
measuring mode. Then  slowly sweep  the laser back 
and forth respectively up and down over the desired 
target point - see figure {

F, G

} -  (e.g. a corner in the 

room). 
Press 

ON/MEASURING 

- key {

A, 1

} again and the 

continuous measurement will be stopped. The 
current values for maximum and minimum distances 
are shown in the display as well as the last measured 
value in the main line.

Functions

Addition / Subtraction

Take the first measurement, addition is executed by 
pressing the 

PLUS

 - key {

A, 2

} and subtraction by 

pressing the 

MINUS

 - key {

A, 7

}, then take the next 

measurement. This process can be repeated as many 
times as is required. The result is displayed in the 
main line, whilst the last measurement taken is also 
displayed. Pushing the 

CLEAR

 - key {

A, 5

} undoes the 

last step. 

Содержание TLM210

Страница 1: ...77 921...

Страница 2: ...min max 1 2 3 4 5 6 7 8 10 11 12 9...

Страница 3: ......

Страница 4: ...ons Content Start up 1 Operation 2 Measuring 3 Functions 3 Appendix 4 Start up Inserting Replacing Batteries See figure C Push locking mechanism to the right and push the cover of the battery compartm...

Страница 5: ...ment 10 Three auxiliary lines e g previous values 11 Maximum value of continuous measurement 12 Stack recall Selecting Units Press UNITS key A 4 long to select desired unit Possible units Operation Sw...

Страница 6: ...1 again The measured distance is displayed immediately in the chosen unit Minimum Maximum Measuring This function allows the user to measure the minimum or maximum distance from a fixed measuring poin...

Страница 7: ...he historical storage In order to leave the history press either CLEAR key A 5 ON MEASURING key A 1 or the AREA VOLUME key A 3 Press and hold the HISTORY key A 4 until a beep allows the user to take t...

Страница 8: ...s deflects the laser beam and measurement errors can occur Against non reflective and dark surfaces the measuring time can be increased Care Do not immerse the unit in water Wipe off dirt with a damp...

Страница 9: ...a two 2 year warranty from Stanley Works For more information on the warranty please go to www stanleyworks com In case of any questions concerning the warranty please contact the dealer who you purc...

Страница 10: ...L C A 7 4 6 6 5 3...

Отзывы: