Stanley TLM 130i Скачать руководство пользователя страница 6

12/146

10.2 Area

Â

Press key 

7

 once.

The area symbol appears on the display.

Â

Press key 

4

 and measure the first distance.

(e.g. length).

Â

Press key 

4

 and measure the second distance.

(e.g. width).

The device displays the result in the summary row 
and the respective measured distance to the next 
measurement in the second row.

10.3 Room volume

Â

Press key 

7

 twice.

The volume symbol appears on the display.

Â

Press key 

4

 and measure the first distance

(e.g. length).

Â

Press key 

4

 and measure the second distance

(e.g. width).

Â

Press key 

4

 and measure the third distance

(e.g. height).

The device displays the result in the summary row 
and the respective measured distance to the next 
measurement in the second row.

10.4 Pythagoras

Â

Press key 

7

 three times.

The Pythagoras symbol appears on the dis-
play.

Â

Press key 

4

 and measure the first distance

(diagonal measurement).

Â

Press key 

4

 and measure the second distance

(horizontal measurement).

The device displays the result in the summary row 
and the respective measured distance to the next 
measurement in the second row.

11 Troubleshooting

Â

If the message 

Error

 does not disappear after

switching on the device repeatedly, please
contact the dealer.

Â

If the message 

InFo

 appears with a number,

observe the instructions in the following table.

12 Technical data

No.

Cause

Correction

204 Calculation error

Perform measurement 
again.

252 Temperature too high

Let the device cool 
down.

253 Temperature too low

Warm the device up.

255 Reception signal too 

weak, measuring time 
too long

Change target surface 
(e.g. white paper).

256 Input signal too high

Change target surface 
(e.g. white paper).

257 Measuring error, too 

much background light

Shadow the target 
area.

258 Measurement outside 

of the measuring range

Mind the range.

260 Laser beam interrupted Repeat the measure-

ment.

Range

0.1 m to 30 m
0.33 ft to 98 ft

Measuring accuracy (2 

σ

typ.: ± 2.0 mm*
± 0.12 in*

Smallest unit displayed

1 mm
1/16 in

Laser class

2

Laser type

635 nm, < 1 mW

Automatic switch-off

after 180 s

Continuous measuring

yes

Addition/Subtraction

yes

Dimension (H x D x W)

119 x 64 x 28 mm
4.67 x 2.52 x 1.10 in

Battery durability
(2 x AAA)

up to 3000 measure-
ments

Weight

100 g

Stanley TLM 130i.book  Page 12  Tuesday, February 5, 2008  5:00 PM

Содержание TLM 130i

Страница 1: ...Stanley TLM 130i book Page 1 Tuesday February 5 2008 5 00 PM...

Страница 2: ...A D E F B C Stanley TLM 130i book Page 2 Tuesday February 5 2008 5 00 PM...

Страница 3: ...els and caution labels are not removed Do not open the device with tools screwdri ver etc Make sure that the device is not converted or modified Avoid using accessories of other producers that are not...

Страница 4: ...isplay See drawing D 8 measuring plane 9 area room volume pythagoras 10 battery symbol 11 second row 12 fractions exponents 13 units 14 summary row 15 addition subtraction 7 Initial operation Insert t...

Страница 5: ...ain 8 5 Unit setting Metric system is the standard setting To change the unit hold key 6 for several seconds With every keypress the device switches to the next unit Possible units feet inch fractiona...

Страница 6: ...next measurement in the second row 11 Troubleshooting If the message Error does not disappear after switching on the device repeatedly please contact the dealer If the message InFo appears with a numb...

Страница 7: ...y aim at other persons The eye is usually protected by preventive reactions such as the eyelid closure reflex Labels Position of the type label see drawing C 13 Care Clean the device with a damp soft...

Страница 8: ...device and the batteries appropriately Caution Damage to property due to inappropriate dis posal Dispose of the device and the batteries according to the national country specific disposal direc tive...

Страница 9: ...Stanley TLM 130i book Page 145 Tuesday February 5 2008 5 00 PM...

Страница 10: ...146 Stanley TLM 130i book Page 146 Tuesday February 5 2008 5 00 PM...

Отзывы: