background image

14

AIR CONTROLS

The  stove has two air controls, the controls operate
by pushing in to close and pull out to open, the sec-
ondary air control on the left hand side controls air
entering  the  stove  via  the  air  wash  over  the  glass
and the air holes at the rear of the firebox. The pri-
mary air control on the right hand side controls the
air entering the stove under the grate. When lighting
the stove bothe air controls can be pulled out fully to
allow the maximum air supply to the stove, when the
fire becomes established the air controls should be
adjusted depending on the fuel used to give a con-
trolled burn. For setting of air controls during when
the  fire  is  established  view  the  above  table  of  air
control settings.

RECOMMENDED FUELS

All fuels should be stored under cover and kept
as dry as possible prior to use.

This appliance has been tested using seasoned
wood logs and manufactured briquetted smokeless
fuel (Ancit) for closed appliances, sized between
20g  and  140g.  Other  fuels  are  commercially  avail-
able and may give similar results. Wood logs up to
406mm long are suitable. All fuels should be stored
under cover and kept as dry as possible prior to use.
Do not use fuels with a Petro-coke ingredient as this
may cause the grate to overheat, causing damage.
Reduced outputs will result when fuels of lower
calorific values are used. Never use gasoline or
gasoline type lantern fuel, kerosene, charcoal lighter
fluid or similar liquids to start or freshen up a fire in
this heater. Keep all such liquid well away from the
heater at all times. Operate the stove only with the
fuelling door closed except for re-fuelling.

This  stove  has  obtained  HETAS  Ltd  approval  for
burning  natural  and  manufactured  smokeless  fuels
and  wood  logs  only  as  detailed  in  recommended
fuels  below.    HETAS Approval  does  not  cover  the
use of other fuels either alone or mixed with the rec-
ommended fuels listed, nor does it cover instructions
for the use of other fuels.

Primary air
control.

Secondary air
control

AIR CONTROL SETTINGS

Anthracite

Fully Open

Fully Closed

0-80% Open

Fully Closed

Coal

Fully Open

Fully Open

0-80% Open

0-50% Open

Wood/ Turf

Fully Open

Fully Open

0-10% Open

0-80% Open

Fuel

Ignition

Controlled Burn

Primary

Secondary

Primary

Secondary

Fig.9

Содержание Tara Non Boiler Eco

Страница 1: ...nfirm persons should be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled When using the boiler stove in sit...

Страница 2: ...12 Location 9 13 Installation Clearances 9 14 Floor Protection 9 15 Specification Non boiler model 10 16 Technical Data 10 17 Handover 11 18 Operating Instructions 11 19 Suitable Fuels 11 20 Lighting...

Страница 3: ...TABLE OF CONTENTS PAGE NO 33 Vitreous Enamel Cleaning 17 34 Glass Cleaning 17 35 Glass Replacement 17 36 Exploded view 18 37 Trouble Shooting 19 3...

Страница 4: ...ed as per the requirements of the manual Failure to comply with the Installation requirements or Building Regulations will void your warranty Waterford Stanley reserve the right to replace any part du...

Страница 5: ...materials must be adhered to as described in the Clearance to Combustible section 8 The stove must be installed on a floor protector that covers the area under the stove and extends 18 to the front 8...

Страница 6: ...o asbestos If there is a possi bility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment Metal Parts When installing...

Страница 7: ...nd turbulence can be created by the roof and adjacent objects Wind effects can also be created by natural land contours To minimise the wind effects the flue termination point should be located a mini...

Страница 8: ...All materials used in the manufacture of air vents should be such that the vent is dimensionally stable and corrosion resistant The effective free area of any vent should be ascer tained before instal...

Страница 9: ...the correct size and unob structed for the appliance in use Where such a installation exists a test for spillage should be made with the fan or fans and other appli ances using air in operation at ful...

Страница 10: ...mass flow g s 4 5 5 6 Gross Weight kg 135 Flue Outlet Diameter mm 150 Wood Log Size mm 300 N A Mean CO emission at 13 O2 0 10 0 11 Mean CnHm at 13 O2 Nmg m3 43 58 Mean NOx at 13 O2 Nmg m3 82 97 DIN P...

Страница 11: ...uard to BS 6539 in the pres ence of children aged and or infirm persons OPERATING INSTRUCTIONS WARNINGS If there is a possibility that a part of the heating system may be frozen you should not light t...

Страница 12: ...tart or freshen up afire in this heater 9 When a hot bed of fuel is established add the normal fuel and adjust the spin valve to the required setting 10 To shut the fire down do not add fuel make sure...

Страница 13: ...sing unnecessary damage Close the ash door between removing and replacing the ashpan 9 Clean the chimney at least twice a year 10 Burning soft fuels such as timber and peat will stain the glass Regula...

Страница 14: ...y give similar results Wood logs up to 406mm long are suitable All fuels should be stored under cover and kept as dry as possible prior to use Do not use fuels with a Petro coke ingredient as this may...

Страница 15: ...sh is disposed of replace the empty ashpan OVERNIGHT BURNING To achieve an overnight or a low burn rate close the Secondary air control fully close the primary air con trol or leave it marginally open...

Страница 16: ...lwork 16 TO REPLACE FIRE GRATE Remove the 3 fire fence at the front of the stove unscrew the pull rod knob from the pull rod bar locat ed at the front of the stove in the bottom left hand corner Pull...

Страница 17: ...soapy damp cloth followed by a polish with a clean dry duster 2 For stubborn deposits a soap impregnated pad can be carefully used on the vitreous enamel 3 Only products recommended by the Vitreous En...

Страница 18: ...TARA NB EXPLODED VIEW 18...

Страница 19: ...carpentry off cuts plywood pallets etc Smokes When Lighting Up Flue duct is cold Burn paper and kindling to increase heat Smokes While Burning Draught is insufficient Down Draught Room is in decompres...

Страница 20: ...N00841AXX REV 001 NH 030519 20 Manufactured by Waterford Stanley Ltd Unit 401 403 IDA Industrial Estate Cork Road Waterford Ireland Tel 051 302300 Fax 051 302315...

Отзывы: