background image

11

ENGLISH

(Original instructions)

Warning:

 Under extreme working conditions, 

conductive dust and grit may accumulate on the 
housing interior when handling metal workpieces. 

This could create an electric shock hazard as it weakens the 

protective insulation in the grinder.

To avoid accumulation of metal chips in the interior of the 
grinder, we recommend cleaning the ventilation ducts daily. 
Refer to Maintenance.

Using Grinding Wheels

Warning:

 Metal powder accumulates. Excessive 

use of the grinding wheel on metals may 
increase the risk of electric shock. To reduce the 

risk, insert the RCD before use and clean the ventilation 
ducts daily. Follow the maintenance instructions below to 
blow dry compressed air into the ventilation ducts.

Maintenance

Stanley power tools have been designed to operate over a 
long period of time with minimal maintenance. Continuous 
satisfactory operation depends upon proper tool care and 

regular cleaning.

Warning: To minimize the danger of serious 
personal injury, please switch off the tool 
power and disconnect all plugs before 

adjusting or removing/installing any accessory. 

Before 

reassembling the tool, press and release the trigger switch 
to make sure the tool is already switched off.

Lubrication

This power tool does not require separate lubrication.

Cleaning

Warning:

 Once visible dust accumulates on the 

ventilation ducts and the surrounding, 
immediately use dry air to blow away dust and 

grit out of the interior of the housing. You need to wear 

approved eye and facial protective gear when performing 

this process.

Warning:

 Never use solvents or harsh chemicals 

to clean non-metal parts of the material of the 
parts. Use only mild soap and damp cloth to 

clean the tool. Never let any liquid get inside the tool; never 
immerse any part of the tool into liquid.

Accessories

Warning:

 Excluding accessories provided by 

Stanley, all other accessories have not been 

tested for product compatibility. Using such accessories 
together with this tool may cause safety hazards. To 
minimize the risk of personal injury, we recommend you to 
use only Stanley accessories with this product.

Please inquire at your dealer for more information regarding 

suitable accessories.

Technical Data

 

 

STGS7115

Input power 

710

Voltage  

220-240

Frequency  

Hz 

50/60

No-load speed/rated speed 

min

-1

 

11,000

Wheel diameter 

mm 

115

Grindig wheels thickness 

mm 

6

Type of wheel 

 

27

Spindle diameter 

 

M14

Weight 

kg 

1.8

Содержание STGS5115

Страница 1: ...STGS7115 English Page 4...

Страница 2: ...ENGLISH 2 Original instructions Figure 1 b c c d h f g e i k Figure 2 Figure 3 n a...

Страница 3: ...3 ENGLISH Original instructions Figure 5 Figure 6 Figure 4 h f d e 15o 30o A B...

Страница 4: ...ng a power tool Distractions can cause you to lose control 2 Electrical safety a Power tool plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed groun...

Страница 5: ...se instructions to operate the power tool Power tools are dangerous in the hands of untrained users e Maintain power tools Check for misalignment or binding of moving parts breakage of parts and any o...

Страница 6: ...rforming an operation where the cutting accessory may contact hidden wiring or its own cord Cutting accessory contacting a live wire may make exposed metal parts of the power tool live and could give...

Страница 7: ...ust be used only for recommended applications For example do not grind with the side of cut off wheel Abrasive cut off wheels are intended for peripheral grinding side forces applied to these wheels m...

Страница 8: ...ure to check that the power suuply corresponds to the voltage on the rating plate Your Stanley tool is equipped with double insulation hence it does not require to be earthed When the power cord is da...

Страница 9: ...face the wheel 5 Press the spindle lock b and prevent the spindle e from rotating until it locks in place 6 Use the pin spanner to tighten the outer ange h Preparation Before Use Attach the safety gu...

Страница 10: ...ditions Allow the grinder to run up to full speed before touching the work surface Lift the tool from the surface before turning the tool off Allow the tool to stop rotating before putting it down Sli...

Страница 11: ...Before reassembling the tool press and release the trigger switch to make sure the tool is already switched off Lubrication This power tool does not require separate lubrication Cleaning Warning Once...

Страница 12: ...f your nearest authorised repair agent by contacting your local Stanley of ce at the address indicated in this manual Alternatively a list of authorised Stanley repair agents and full details of our a...

Страница 13: ...N419083 12 2014...

Страница 14: ...44600525 Fax 974 44601338 Al Muftah Service Centre Al Wakrah Road P O Box 875 Doha Qatar Tel 974 44650880 44650110 44446868 Fax 974 44441415 44662599 SAUDI ARABIA Al Bahr Mohamed Ahmed Bin A f Est P O...

Отзывы: