NEVER LEAVE DEHUMIDIFIER UNATTENDED WHILE CONNECTED TO A POWER SOURCE
© 2016 Obelis S.A Registered Address:
Bd. Général Wahis, 53, 1030 Brussels, Belgium
Starting the Dehumidifier:
1.
Connect the dehumidifier to the proper
electrical power.
2.
Press power button to turn on the unit.
3.
The digital display will show the ambient
humidity in the room.
4.
Choose fan speed: +/−
5.
Choose desired humidity setting, Continuous
(CO) or Automatic (AU).
Humidity Settings:
Continuous Mode (CO)
–
Continuous mode will keep the relative
humidity at the chosen constant point.
–
The setting range is from 50%-80% relative
humidity.
–
When the ambient humidity is 3% lower than
the chosen humidity setting, the compressor
will stop.
–
When the ambient humidity is 3% higher than
the chosen humidity setting, the compressor
will re-start and maintain the chosen humidity
setting.
Automatic Mode (AU)
–
Automatic mode will keep the ambient
humidity constant in relation to the ambient
temperature of the space.
–
When the ambient temperature is lower than
5 ºC, the compressor will shutdown while the
unit remains on.
–
When the ambient temperature is between
5 ºC and 20 ºC, the space will be kept at 60%
relative humidity automatically.
–
When the ambient temperature is between
21 ºC and 27 ºC, the space will be kept at
55% relative humidity automatically.
–
When the ambient temperature is higher than
28 ºC, the space will be kept at 50% relative
humidity automatically.
Operation
Continuous Mode Display
Automatic Mode Display
9
Figure 1
Figure 2