Problem
Possible Cause
Solution
Burner does not light
1. Air in gas line.
2. Gas pressure from cylinder too low
3. Fuel cylinder valve turned off
4. Obstruction in air passageway
5 Dirt in nozzle
6. Safety switch in cylinder valve
engaged
1. Depress the control knob for at least 30
seconds to remove any air in line.
2. Check fuel cylinder pressure. Tank may be
empty.
3. Open fuel cylinder valve.
4. Inspect and clean heater housing
5. Blow out, or otherwise clean the nozzle
6. Close fuel cylinder valve. Wait one minute for
switch to click off. Re-open fuel cylinder valve
slowly
Heater stops running by
itself
1. Thermocouple damaged
2. Gas control valve damaged
3. Gas leak
4. Out of fuel
5. Thermocouple not in contact with
pilot flame
1. Have the thermocouple replaced by a quali-
fied service person,
2. Have the gas control valve replaced by a
qualified service person.
3. Check all connections for leaks. Any repairs
must be made by a qualified service person.
4. Replace fuel cylinder.
5. Clean inside of burner housing
No spark is created when
ignited
1. Gas control valve damaged
2. Loose or disconnected igniter wire
3. Broken igniter wire
1. Have the gas control valve replaced by a
qualified service person.
2. Tighten or reconnect loose wire
3. Have the ignitor wire replaced by a qualified
service person.
The appliance does not stay
lit smoothly or evently.
1. The incorrect fuel is used or the
incorrect pressure is used.
1. Check fuel cylinder to assure the correct gas
is being used at the correct pressure.
Troubleshooting Guide
Specifications subject to change without notice
4
THERMAL POWER (kW/BTU)
3.4 / 11,687
IGNITION
PIEZO
FUEL CONSUMPTION (g/h)
246
WEIGHT (kg)
2.24
MAX OPERATING HOURS
129
GAS CYLINDER SIZE
5kg-15kg
HOSE TYPE (WHEN SUPPLIED)
Rubber or Plastic hoses
complied with BS EN
16436-1:2014
HOSE LENGTH (WHEN SUPPLIED)
1.0m-1.5m
REGULATOR TYPE
(WHEN SUPPLIED)
Pressure regulator
complied with BS EN
16129:2013
Specifications
CZ, ES, FR, GB, IT, PT
G30 Butane at 28-30 mbar
G31 Propane at 37 mbar
G30 Butane at 30 mbar
G31 Propane at 30 mbar
I3+(28-30/37)
G30 Butane at 50 mbar
G31 Propane at 50 mbar
G31 Propane at 30 mbar
Country of
Destination
Gas Type and
Supply Pressure
Gas
Category
PL
I3B/P(30)
DK, FI, IT, NL, RO, SE
I3B/P(50)
I3B/P(37)
G30 Butane at 37 mbar
G31 Propane at 37 mbar
DE
I3P(30)
I3P(37)
I3P(50)
G31 Propane at 37 mbar
G31 Propane at 50 mbar
NL
CZ, ES, FR, GB, IE, PT
DE, ES, GB, NL