background image

8

9

Note:

 

If the power/fault LED flashes red, the unit emits three beeps every five seconds, the 120W and 800W LED indicators do not light and the AC outlets 

and USB charging port shut down, a fault condition has occurred. Refer to the Protective Features Section and the Troubleshooting Section of this 

Instruction Manual.

CAUTION

• 

The cable and fuse sizes given here are a general recommendation. You should always consult your National Electrical Code 

prior to beginning each specific installation.

• 

Loose connectors may cause overheated wires and melted insulation.

• 

Check to make sure you have not reversed the polarity. Damage due to reversed polarity is not covered by our warranty.

IMPORTANT CABLE INFORMATION

Substantial power loss and reduced battery operating time results from inverters installed with cables that are not able to 

supply full power. Symptoms of low battery power can result from cables that are either excessively long or an insufficient 

gauge. 

Connection To Load

The Power Inverter is equipped with dual standard North American three-prong type outlets. Plug the cord from the equipment 

you wish to operate into the AC receptacle(s). Make sure the combined load requirement of your equipment does not exceed 

maximum continuous power.
The Power Inverter is engineered to be connected directly to standard electrical and electronic equipment in the manner 

described above. Do not connect the Power Inverter to household or RV AC distribution wiring. Do not connect the Power 

Inverter to any AC load circuit in which the neutral conductor is connected to ground (earth) or to the negative of the DC 

(battery) source.

WARNING: Do not connect to AC distribution wiring!

Operation of the 120 Volt AC Outlets

 1. Connect the inverter to a functioning 12 volt DC power source as described in this Instruction Manual. If using the 12 Volt 

DC Vehicle Accessory Adapter, rotate the vehicle accessory plug slightly to make sure there is good contact. Make sure there 

is adequate space for proper ventilation of the inverter.

 2. Press the Translucent On/Off Button to turn the inverter on.

 3. Depending on the power source, either the 120W LED Indicator or both the 120W and 800W LED Indicators will light. 

If these LEDs do not light or if the power/fault LED flashes red, please refer to the Protective Features Section and the 

Troubleshooting Section of this Instruction Manual.

 4. Plug the (110/120 volt AC) appliance into one of the Inverter’s three-prong AC outlet and operate normally.

Notes: 

This inverter has two three-prong AC outlets that can be rotated forward and upward to maximum of 90 degrees to adjust the orientation. Do not 

attempt to forcibly rotate the AC outlets beyond their maximum angle.

 

Ensure that the wattage of all equipment simultaneously plugged into the inverter does not exceed 120 watts continuous through the supplied DC 

Vehicle Adapter plug, and 800 watts continuous via the supplied Battery Clips with Slide-In Connectors. 

 

The Inverter will not operate appliances and equipment that generate heat, such as hair dryers, electric blankets, microwave ovens and toasters.

 

Remember to disconnect the inverter from any power source when not in use.

Operation of the USB Charging Port

 1. Connect the inverter to a functioning 12 volt DC power source as described in this Instruction Manual. If using the 12 Volt 

DC Vehicle Accessory Adapter, rotate the vehicle accessory plug slightly to make sure there is good contact. Make sure there 

is adequate space for proper ventilation of the inverter.

 2. Press the Translucent On/Off Button to turn the inverter on.

 3. Depending on the power source, either the 120W LED Indicator or both the 120W and 800W LED Indicators will light. 

If these LEDs do not light or if the power/fault LED flashes red, please refer to the Protective Features Section and the 

Troubleshooting Section of this Instruction Manual.

 4. Plug the USB-powered device into the inverter’s USB Charging Port and operate normally.

Notes: 

 This unit’s USB Charging Port does not support data communication. It only provides 5 volts/2A DC power to an external USB-powered device.

 

Not all mobile phones are provided with a charging cable, they are normally data cables which are not supported by this device - please check with 

your mobile phone manufacturer for the correct charging cable.

 

Some USB-powered household electronics may not operate with this USB charging/power port. Check the manual of the corresponding electronic 

device to confirm that it can be used with this type of USB charging/power port. 

 

Remember to disconnect the inverter from any power source when not in use.

• 

Press the Translucent On/Off Button to turn the inverter on.

• 

The 120W LED Indicator will light, indicating that the inverter is operating properly and is ready to power appliances that 

draw up to 120 watts continuous.

Notes: 

If the power/fault LED flashes red, the unit emits three beeps every five seconds, the 120W LED indicator does not light and the AC outlets and USB 

charging port shut down, a fault condition has occurred. Refer to the Protective Features Section and the Troubleshooting Section of this Instruction 

Manual.

 

If the inverter does not work when using the vehicle accessory outlet, make sure the ignition/accessory switch is actually powering the accessory outlet. 

Some vehicles require the ignition switch to be turned on.

 

Ensure that the wattage of all equipment simultaneously plugged into the inverter does not exceed 120 watts continuous 

 

Most vehicle accessory outlet circuits have fuses rated at 15 to 20 amps or greater. To operate at full wattage, either use the battery clip cable 

(supplied) or directly wire to the power source with user-supplied wire and fuse. 

CAUTIONS

• 

Connect directly to power source using the included Battery Clips when operating above 120 watts.

• 

Do not use with positive ground electrical systems.

• 

Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter.

CONNECTING TO A POWER SOURCE USING THE PROVIDED BATTERY CLIPS WITH SLIDE-IN CONNECTORS

Use the provided Battery Clips (with cables and slide-in connectors) to connect the Power Inverter directly to the 12 volt power 

source as follows:

 1.  Check to make sure the power/fault LED inside the translucent On/Off button is not lit and that no flammable fumes are 

present in the installation area.

 2. Turn the red plastic cap (counterclockwise) on the inverter’s positive (+) cable post and remove. Attach the positive 

connector at the end of the red battery clip cable into the groove of the positive (+) cable post. Replace the cap and turn 

clockwise to secure. Do not over-tighten.

 3. Connect the red battery clip to the POSITIVE terminal of the battery.

 4. Turn the black plastic cap (counterclockwise) on the inverter’s negative (–) cable post and remove. Attach the negative 

connector at the end of the black battery clip cable into the groove of the negative (–) cable post. Replace the cap and turn 

clockwise to secure. Do not over-tighten.

 5. Connect the black battery clip to the NEGATIVE terminal of the battery.

 6. Make sure that all connections between cables and terminals are secure.

 7. Press the translucent On/Off Button to turn the inverter on.

 8. The 120W and 800W LED Indicators will light, indicating that the inverter is operating properly and is ready to power 

appliances that draw up to 800 watts continuous.

Note:

 

If the power/fault LED flashes red, the unit emits three beeps every five seconds, the 120W and 800W LED indicators do not light and the AC outlets 

and USB charging port shut down, a fault condition has occurred. Refer to the Protective Features Section and the Troubleshooting Section of this 

Instruction Manual.

DIRECT HARDWIRING TO POWER SOURCE (OPTIONAL CONNECTION METHOD; HARDWARE NOT INCLUDED)
Use #8 AWG wire if the inverter to power source connection is 4 feet or less. For cable lengths up to 10ft use #6 AWG wire.* In 

either case, protect the positive (+) wire from shorts by installing a 150 amp fuse or circuit breaker close to the DC power source 

(battery) terminal. 

*For cable lengths exceeding 10 feet from inverter to battery, contact manufacturer for additional information.

The cable, fuse holder and fuse (not supplied) can be purchased at an electrical supply company. Manufacturer provides the 

installation cable set (refer to the “Installation” section of this manual).

 1.  Check to make sure the power/fault LED inside the translucent On/Off button is not lit and that no flammable fumes are 

present in the installation area.

 2. Identify the positive (+) and negative (–) DC power source (battery) terminals.

 3. Install a fuse holder or breaker close to the positive (+) terminal of the DC source (battery).

 4. Connect a length of wire on one side of the fuse holder or circuit breaker. Connect the other end of the wire to the positive 

(+) terminal of the inverter.

 5. Connect a length of wire between the inverter’s negative (–) terminal and the DC power source negative (–) terminal.

 6. Connect a short length of wire to the other terminal of the fuse holder or circuit breaker. Mark it “positive” or “+”.

 7. Connect the free end of the fuse or breaker wire to the positive (+) terminal of the DC power source (battery).

 8. Insert a fuse appropriate to the inverter in the fuse holder.

 9. Press the translucent On/Off Button to turn the inverter on.

10. The 120W and 800W LED Indicators will light, indicating that the inverter is operating properly and is ready to power 

appliances that draw up to 800 watts continuous.

11. Test the inverter by turning it on and plugging in a 120 watt lamp or equipment. If the inverter is not properly operating, 

refer to the Protective Features Section and the Troubleshooting Section of this Instruction Manual.

PI800PS_ManualENSP_051116.indd   8-9

5/11/2016   11:17:57 AM

Содержание PI800PS

Страница 1: ...S CONPUERTODECARGAUSB MANUAL DE INSTRUCCIÓN SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE CONSERVE ESTE MANUAL PARA FUTURAS CONSULTAS 2016 Baccus Global LLC Boca Raton FL 33432 877 571 2391 PI800PS English page 3 Español pagina 12 x PI800PS_ManualENSP_051116 indd 20 1 5 11 2016 11 17 55 AM ...

Страница 2: ...nnectors CARACTERÍSTICAS 1 Botón translúcido de encendido apagado y indicador de poder de fallo 2 Indicador LED de 120 Vatios 3 Indicador LED de 800 Vatios 4 Pivotante tomacorrientes de 120 voltios CA de tres clavijas 5 Puerto de carga USB 6 Ranuras de ventilación 7 Soportes de montaje total de 4 2 a la izquierda y 2 a la derecha 8 Negro poste de cable negativo debajo de la tapa 9 Ventiladores de ...

Страница 3: ... The modified sine wave produced by this inverter has an RMS root mean square voltage of 120 volts Most AC voltmeters both digital and analog are sensitive to the average value of the waveform rather than the RMS value They are calibrated for RMS voltage under the assumption that the waveform measured will be a pure sine wave These meters will not correctly read the RMS voltage of a modified sine ...

Страница 4: ...nto the socket on the rear of the unit when there are NO battery clips connected to the unit This is a safety feature and the design of the plug also covers the positive terminal to prevent both leads being connected at the same time Connect the inverter to the power source by inserting the DC Accessory Outlet Plug firmly into the accessory outlet of a vehicle or other DC power source of this inve...

Страница 5: ...erly and is ready to power appliances that draw up to 120 watts continuous Notes If the power fault LED flashes red the unit emits three beeps every five seconds the 120W LED indicator does not light and the AC outlets and USB charging port shut down a fault condition has occurred Refer to the Protective Features Section and the Troubleshooting Section of this Instruction Manual If the inverter do...

Страница 6: ...interference may still be visible especially when the TV signal is weak Try the following to improve the picture 1 Move the Inverter as far away as possible from the TV set the antenna and the antenna cables Use a short AC extension cord if necessary 2 Adjust the orientation of the antenna cables and the TV power cord to minimize interference 3 Make sure that the antenna feeding the TV provides an...

Страница 7: ...V 0 25 26 50 51 120 101 150 0 7 6m 7 6 15 2m 15 2 30 4m 30 4 45 7m 240V 0 50 51 120 101 200 201 300 0 15 2m 15 2 30 4m 30 4 60 9m 60 9 91 4m Capacidad nominal en amperios Más No más Medida de conductor estadounidense AWG que que 0 6 18 16 16 14 6 10 18 16 14 12 10 12 16 16 14 12 12 16 14 12 No recomendado ADVERTENCIA PARA REDUCIR EL RIESGO DE DESCARGA ELÉCTRICA No conecte al cableado de distribuci...

Страница 8: ...roducto presenta un funcionamiento anormal como operación intermitente zumbido y similares Nota Algunos computadoras portátiles pueden no funcionar con este inversor ADVERTENCIA Si el producto no funciona normalmente para reducir el riesgo de lesiones y daños a la propiedad apague el producto de inmediato y desenchúfelo del inversor Consumo de corriente real versus calificado del equipo La mayoría...

Страница 9: ...prar en una empresa de suministro eléctrico Fabricante proporciona el juego de cables de instalación consulte la sección Instalación de este manual 1 Revise para asegurarse de que potencia y fallas LED dentro el translúcido botón de encendido apagado no se enciende y que no haya vapores inflamables están presentes en el área de instalación 2 Identifique los terminales positivo y negativo batería d...

Страница 10: ...sin nieve y que se utilice un cable de antena blindado de alta calidad Problemas frecuentes de potencia de salida El voltaje de entrada está por debajo de 10 5 voltios Recargue la batería auto o compruebe la fuente de CC El equipo que se opera consume mucha energía Reduzca la carga a un máximo de 800 vatios si conecta la unidad mediante pinzas para batería Reduzca la carga a un máximo de 120 vatio...

Отзывы: