Dimension
Terminal Position
Minimum
Distance (mm)
A
Directly below an openable window or other opening
300
e.g. air brick
B
Below gutters, soil pipes or drain pipes
300
C
Below eaves
300
D
Below balconies or car port roofs
600
E
From vertical drain pipes and soil pipes
75
F
From internal or external corners
600
G
Above ground, roof or balcony level
300
H
From a surface facing a terminal
600
I
From a terminal discharging towards another terminal
600
J
From an opening in a car port (e.g. door, window)
1200
K
Vertically from a terminal on the same wall
1500
L
Horizontally from a terminal on the same wall
300
Fig.5
Fig.6
12