background image

ID07 User Manual | 11

What is the ID07 Hydraulic Impact Drill?

ID07 is a high torque impact wrench used for tightening nuts, driving lag 
bolts or auguring through difficult materials, such as telephone poles.

Specifications

Pressure

2000 PSI (140 BAR)

Flow

4-12 GPM (15-46 LPM)

RPM

7679 @ 12 GPM (46 LPM)

Max. Pressure

2500 PSI (172 BAR)

Max. Relief Pressure

2100 PSI (145 BAR)

Recommended Back 
Pressure

250 PSI (17 BAR) - Can be used with higher 
back pressures with reduced seal life.

Couplers

3/8 Inch, NPT Pipe Fitting

Port Size

-8 SAE O-ring

Tool Weight

7 Lbs. (3.2 Kg)

Tool Size

13 Inches x 5 Inches x 12 Inches

Max. Hydraulic Oil 
Temperature

140°F (60°C)

HTMA/EHTMA Category

Type II - Category D

Underwater Tool Max. 
Depth

1000 Feet (305 M)

Recommended Hose Diameters for Underwater Applications
Depth

8 GPM (30 LPM)

12 GPM (45 LPM)

100 Feet (31 Meters)

5/8 Inches (16 mm)

5/8 Inches (16 mm)

300 Feet (91 Meters)

3/4 Inches (19 mm)

1 Inch (25.4 mm)

600 Feet (183 Meters)

1 Inch (25.4 mm)

1 Inch (25.4 mm)

1000 Feet (305 Meters)

1 Inch (25.4 mm)

1 1/4 Inches (32 mm)

Sound & Vibration Declaration

Measured A-Weighted sound power 
level

101.1 dBA

Uncertainty

3.39 dBA

Measured A-Weighted Sound Pressure

93.1 dBA

Uncertainty

3.39 dBA

Values determined according to noise test code given in ISO 15744, 11203 
and 3744.

Declared vibration emission value in accordance with EN ISO 28927-2.

Declared Vibration Emission Value:

8.5 m/sec²

Uncertainty

1.74 m/sec²

Parts of an ID07 - Detail A

Circuit Type “D” Decal

Serial Number & Year of Manufacture

Read the Manual Decal (CE Models)

CE Decal (CE Models)

Pressure Warning Decal (Non-CE Models)

Rotation Direction Decal

Sound Power Decal (CE Models)

Electrical Warning Decal (Non-CE Models)

Handle

Female Hydraulic Coupler

Male Hydraulic Coupler

10 

Trigger Guard

11 

Trigger

12 

Impact Mechanism

13 

Bit Retainer

14 

Tool Name Tag

15 

Open Center / Closed Center Decal

16 

Rotation Direction Spool

Tool Setup

Do not install or change tool accessories while the 
hydraulic power source is connected. Accidental 
engagement of the tool can cause serious injury. 
Disconnect the hydraulic power source before installing 
or changing accessories.

1.  Disconnect the tool from the hydraulic power source.

Install the Assist Handle - Detail B

ID07 may be equipped with an assist handle as an accessory (see “ID07 
Accessories” on page 12). The assist handle helps to absorb r
eaction 
torque and control the tool. Loss of control can cause personal injury. 
STANLEY recommends you use the assist handle whenever possible.

1.  Place the assist handle over the hammer case.
2.  Tighten the handle.

Set Hydraulic Circuit Type - Detail C

1.  Remove the hex plug on the back of the tool handle.
2.  Turn the selector screw completely clockwise for open center operation 

-OR-

 completely counter clockwise for closed center operation.

3.  Reinstall the hex plug.

Insert Bit - Detail C

Use only impact-rated sockets and accessories. Do not 
use sockets or accessories that are in poor condition. 
These can crack or fracture during operation and can 
become a projectile.

4.  Insert the bit while pushing back on the tool retaining sleeve.
5.  Lock the tool retaining sleeve in place.
Note: Never operate the tool unless the inserted bit is properly retained. Bits 
can become a high velocity projectile.

Choose Drill Rotation Direction - Detail C

6.  Push the rotation direction spool left for clockwise bit rotation 

-OR-

 

right for counter clockwise bit rotation.

Tool Operation - Detail D

Connect to a Hydraulic Power Source

1.  Using a calibrated flow and pressure gauge, check the output of the 

hydraulic power source. Ensure it matches the flow and pressure in 
“Specifications” on page 11. Hydraulic fluid must be 50°F or above. 
Preheat if necessary.

Note: Check the hydraulic power source once a day. Proper flow and 
pressure are critical to maintaining proper tool speed.
2.  Ensure that the hydraulic power source is equipped with a relief valve 

set to open at the maximum relief pressure, see “Specifications” on 
page 11.

3.  Wipe hose couplers with a clean, lint free cloth.
4.  Connect the return hose to the tool port marked “Out”.
5.  Connect the pressure hose to the tool port marked “In”.

Using the Tool

Содержание ID07 Series

Страница 1: ...ment Numero de serie del equipo Matricola dell attrezzatura All Has been manufactured in conformity with Wurde hergestellt in bereinstimmung mit Est fabriqu conform ment Ha sido fabricado de acuerdo c...

Страница 2: ...2 ID07 User Manual 1 3 4 5 7 8 9 6 10 11 12 13 14 15 16 A B C 2 1 2 4 6...

Страница 3: ...ID07 User Manual 3 D E 4 5 6 7 9 2 3 4 5...

Страница 4: ...4 ID07 User Manual 1 2 3 4 6 7 8 9 10 11 12 13 14 16 17 18 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 20 19 15 5 15 F G J N G G H I...

Страница 5: ...ID07 User Manual 5 1 2 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 3 H I...

Страница 6: ...6 ID07 User Manual 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 J K L M N...

Страница 7: ...81501 ID0781506 ID07815AB ID07815AS ID0782001 ID0792001 25 56725 Hose Assembly not shown Models ID07810S ID07815AS 66727 Hose Assembly not shown Models ID07810B ID07815AB 65617 Hose Assembly not shown...

Страница 8: ...dels ID07920 ID0792001 ITEM P N DESCRIPTION 1 31904 Hammer Case 2 32153 Hammer Case Bushing 3 08416 Spring 4 32151 Retainer 5 00012 O ring 6 72900 Anvil 7 31896 Hammer Frame 8 31897 Hammer 9 06757 Ham...

Страница 9: ...ing hazard Operator must start in a work area without bystanders and must assess the risk to bystanders including the risk of serious injury or death caused by the tool or accessories dropped from an...

Страница 10: ...a physician Wear warm clothing when working in cold conditions and keep your hands warm and dry Exposure to vibration can cause disabling damage to the nerves and blood supply of the hands and arms Do...

Страница 11: ...c power source is connected Accidental engagement of the tool can cause serious injury Disconnect the hydraulic power source before installing or changing accessories 1 Disconnect the tool from the hy...

Страница 12: ...mpact mechanism back into the impact housing Grease will extrude out of the bottom hole of the impact mechanism 6 Put the impact housing assembly back onto the tool body Underwater Tool Maintenance Pe...

Страница 13: ...Hydraulic hoses are reversed Install hydraulic hoses properly See Connect to a Hydraulic Power Source on page 11 Defective quick disconnects Inspect for damage or blockage Replace if necessary Incorre...

Страница 14: ......

Страница 15: ......

Страница 16: ...STANLEY Infrastructure 6430 SE Lake Road Portland Oregon 97222 USA 503 659 5660 Fax 503 652 1780 www stanleyinfrastructure com...

Отзывы: