16 ► IBC600
User Manual
Problem
Solution
I can’t install the crimping jaw / The crimping jaw
doesn’t fit into the tool body.
Press and hold the pressure release to fully retract the
piston. Insert the jaw into the tool body.
The jaw pin won’t fit through the hole in the crimping
jaw.
Remove the crimping jaw. Ensure the two halves of the
crimping jaw are aligned.
The jaw pin wont spring back, even though I am pulling
back on the pin lock.
Ensure that the jaw locking hardware is removed (see
page 10
). Press and hold the pressure release to
fully retract the piston. Pull back on the pin lock to eject
the jaw pin.
The tool won’t crimp when I press the trigger.
Ensure the battery is charged. Disengage the trigger
lock.
The InteLED flashes yellow when I activate the tool.
The maintenance interval is about to elapse. Have the
tool serviced as soon as possible.
The tool repeatedly gives me bad crimps / The InteLED
flashes red after every crimp.
Ensure the battery is fully charged. Ensure the
crimping jaw is properly installed and the die is
properly attached. If problem persists, have the tool
serviced as soon as possible.
The tool will not release pressure when the pressure
release is held.
Have the tool serviced immediately.
The tool is leaking hydraulic oil.
Have the tool serviced immediately.
The tool cannot connect to STANLEY Crimp software.
Ensure the tool is connected to the computer via the
USB port and that InteLED is blue. Your computer
may be downloading USB drivers. Check the Windows
system tray for download progress.
The tool is not saving crimp data.
Have the tool serviced as soon as possible.
TROUBLESHOOTING