PREPARATION FOR USE
Do not operate HP210 until you have completed the
following steps:
READ THE ENGINE “OPERATING &
MAINTENANCE INSTRUCTIONS” MANUAL.
CHECK ENGINE CRANKCASE OIL LEVEL
Check the oil level before starting the engine. Make sure
the oil level is at the FULL MARK on the dipstick. Do not
overfill. Use detergent oil classified "For Service SE, SF,
SG" as specified in the engine “Operating & Maintenance
Instructions” manual. See the “Operating & Maintenance
Instructions” manual for oil viscosity grade.
CHECK ENGINE FUEL LEVEL
If fuel level is low, fill with unleaded gasoline (85 octane
minimum).
CHECK HYDRAULIC FLUID
Ensure there is hydraulic fluid in the hydraulic oil tank.
Below is a list of recommended oils.
Brand
Biodegradable
Description
CITGO
No
Hydurance AW32
AMS Oil
No
HVH 32
Exxon Mobil
No
Univis HVI26*
Exxon Mobil
No
DTE 10 Excel
Shell
No
S2 V 32
Chevron
No
Rando HDZ 32
Conoco Phillips
No
Unax AW-WR-32
Clarion (CITGO)
Yes
Green Bio 32
Exxon Mobil
Yes
EAL 224H
Chevron
Yes
Clarity AW32
Terresolve
Yes
Envirologic 132
Shell
Yes
Naturelle HF-E-32
*Recommended for extreme cold temperatures
INSTALL HYDRAULIC CONNECTIONS
STANLEY recommends you use hose lengths of 25 ft/8 m
with 1/2 inch/12.7 mm inside diameter. Hoses must have a
working pressure rating of at least 2500 psi/175 bar. Hose
ends must have male threads compatible with H.T.M.A.
quick disconnect fittings (NPT).
H.T.M.A. approved quick disconnect couplings are installed
to hydraulic hoses so that the direction of oil flow is always
from the male to the female coupling. Additional fittings,
such as reducers or adapter fittings, are not required.
If adapter fittings are used, they must be approved steel
hydraulic fittings meeting a minimum operating pressure
rating of 2500 psi/172 bar. Do not use galvanized pipe
fittings or black pipe fittings.
Use thread tape or pipe joint compound when installing
quick disconnect couplings to hose or tool fittings. Follow
the instructions furnished with the selected thread sealant.
DO NOT OVERTIGHTEN THE FITTINGS.
USING THE 12 VOLT DC OUTLET
A 12 VDC outlet is available for specific models. The DC
outlet is ON at all times.
Accessories left in the 12VDC outlet can drain the
battery if the HP210 is not running.
OPERATION
Содержание HP210 Series