Make  sure  all  couplers  are  wiped  clean  before 

connection.

•  The hydraulic circuit control valve must be in the 

OFF

 position when coupling or uncoupling hydraulic 

tools. Failure to do so may result in damage to 

the  quick  couples  and  cause  overheating  of  the 

hydraulic system.

• 

Always store the tool in a clean dry space, safe from 

damage or pilferage.

• 

Make sure the circuit PRESSURE hose (with male 

quick disconnect) is connected to the 

IN

 port. The 

circuit RETURN hose (with female quick disconnect) 

is  connected  to  the  opposite  port.  Do  not  reverse 

circuit flow. This can cause damage to internal seals.

• 

Always  replace  hoses,  couplings  and  other  parts 

with replacement parts recommended by STANLEY. 

Supply  hoses  must  have  a  minimum  working 

pressure rating of 2500 psi/172 bar.

• 

Do not exceed the rated flow. Rapid failure of the 

internal seals may result. See “SPECIFICATIONS” 

on  page  15  for  correct  flow  rate  and  model 

number. 

• 

Always keep critical tool markings, such as warning 

stickers and tags, legible.

• 

Tool  repair  should  be  performed  by  experienced 

personnel only.

• 

Make  certain  that  the  recommended  relief  valves 

are installed in the pressure side of the system.

• 

Do not use the tool for applications for which it was 

not intended.

In addition to the safety precautions found in 

this manual, observe the following for equipment 

protection and care.

TOOL PROTECTION & CARE

Содержание GD50

Страница 1: ...2014 Stanley Black Decker Inc New Britain CT 06053 U S A 39234 8 2018 Ver 11 USER MANUAL Safety Operation and Maintenance GD50 HYDRAULIC GROUND ROD DRIVER...

Страница 2: ......

Страница 3: ...Note The warranty validation record must be submitted to validate the warranty SERIOUS INJURY OR DEATH COULD RESULT FROM THE IMPROPER REPAIR OR SERVICE OF THIS TOOL REPAIRS AND OR SERVICE TO THIS TOO...

Страница 4: ...messages that follow this symbol to avoid possible injury or death This safety alert and signal word indicates an imminently hazardous situation which if not avoided will result in death or serious in...

Страница 5: ...energizing the hydraulic power source Be sure all hose connections are tight Do not operate the tool at oil temperatures above 140 F 60 C High temperatures can cause operator discomfort Do not operate...

Страница 6: ...RING SYSTEM SYSTEM PRESSURE HOSE MUST ALWAYS BE CON NECTED TO TOOL IN PORT SYSTEM RETURN HOSE MUST ALWAYS BE CONNECTED TO TOOL OUT PORT REVERSING CONNECTIONS MAY CAUSE REVERSE TOOL OPERATION WHICH CAN...

Страница 7: ...TH TO REMOVE DIRT AND MOISTURE AND TEST HOSE FOR MAXIMUMALLOWABLE CURRENT LEAKAGE INACCORDANCE WITH SAFETY DEPARTMENT INSTRUCTIONS SEE OTHER SIDE SIDE 2 D O N O T R E M O V E T H I S T A G 3 DO NOT EX...

Страница 8: ...175 1 25 4 Return 2500 175 13 16 49 60 up to 25 up to 8 5 8 16 Pressure 2500 175 3 4 19 Return 2500 175 13 16 49 60 26 100 8 30 3 4 19 Pressure 2500 175 1 25 4 Return 2500 175 Figure 1 Typical Hose C...

Страница 9: ...operator discomfort at the tool Filter minimum full flow filtration 25 microns 25 microns 25 microns 25 microns Sized for flow of at least For cold temp startup and maximum dirt holding capacity 30 GP...

Страница 10: ...coupler Note The pressure increase in uncoupled hoses left in the sun may result in making them difficult to connect When possible connect the free ends of operating hoses together OPERATING PROCEDUR...

Страница 11: ...he hydraulic system Place the tool to be operated in its operating position Push the valve spool ON to begin operating the tool Push the valve spool OFF to stop operating the tool Turn the hydraulic s...

Страница 12: ...tester gauge reads 600 700 psi 41 48 bar close the valve on the charging assembly hose and remove the charging assembly 7 Turn the gauge end of the tester fully counterclockwise to retract the plunge...

Страница 13: ...se damage to internal seals Always replace hoses couplings and other parts with replacement parts recommended by STANLEY Supply hoses must have a minimum working pressure rating of 2500 psi 172 bar Do...

Страница 14: ...urn line hoses reversed at ports Be sure hoses are connected to their proper ports Mechanical failure of piston or automatic valve Have inspected and repaired by an authorized dealer Rod driver does n...

Страница 15: ...64 8 cm Overall Width 10 inches 25 4 cm Maximum Fluid Temperature 140 F 60 C SERVICE TOOLS DESCRIPTION PART NUMBER O ring Tool Kit General Service of Seals 04337 Split Rings Used with 04910 04908 Flo...

Страница 16: ...50 User Manual GD50 PARTS ILLUSTRATION OLD INLINE VALVE NEW INLINE VALVE NOTE IF YOUR INLINE VALVE DOES NOT CONTAIN THIS PART SEAL CAP ORDER INDIVIDUAL PARTS FROM OLD INLINE VALVE 56 INLINE VALVE ASSE...

Страница 17: ...04954 1 PISTON 38 02022 1 O RING 39 04387 1 WIPER RING 40 04780 1 BACK UP WASHER 41 04386 1 CUP SEAL 42 12139 4 SIDE ROD 43 43527 1 ADAPTOR BLOCK ITEM PART NO QTY DESCRIPTION 44 72592 1 ADAPTOR BLOCK...

Страница 18: ......

Страница 19: ......

Страница 20: ...STANLEY Infrastructure 6430 SE Lake Road Portland Oregon 97222 USA 503 659 5660 Fax 503 652 1780 www stanleyinfrastructure com...

Отзывы: