10
ENGLISH
(Original instructions)
LED work light (Fig H)
When drill is activated by pulling the trigger switch (1), the
integrated LED work light (8) will automatically illuminate the
work area.
Note:
The work light is for lighting the immediate work surface
and is not intended to be used as a flashlight.
Troubleshooting
Problem
Possible cause
Possible solution
Unit will not start.
Battery pack not
installed properly.
Battery pack
not charged.
Check battery pack
installation.
Check battery pack
charging requirements
Unit starts
immediately upon
inserting battery
The switch has
been left in the
“on” position.
The switch must be
moved to “off” to prevent
the tool from immediately
starting when battery
is inserted.
Battery pack will
not charge.
Battery pack not
inserted into charger.
Charger not
plugged in.
Surrounding air
temperature too hot or
too cold.
Insert battery pack into
charger until LED lights.
Plug charger into a working
outlet.
Move charger and battery
pack to a surrounding
air temperature of above
45º C or below +40.5º C.
Unit shuts off
abruptly.
Battery pack has
reached its maximum
thermal limit.
Out of charge. (To
maximize the life of
the battery pack it is
designed to shutoff
abruptly when the
charge is depleted
Allow battery pack to cool
down.
Place on charger
and allow to charge.
Maintenance
Your STANLEY FATMAX tool has been designed to operate
over a long period of time with a minimum of maintenance.
Continuous satisfactory operation depends upon proper tool
care and regular cleaning.
Your charger does not require any maintenance apart from
regular cleaning.
@
Warning!
Before performing any maintenance on
the tool, remove the battery from the tool. Unplug the
charger before cleaning it.
●
Regularly clean the ventilation slots in your tool and
charger using a soft brush or dry cloth.
●
Regularly clean the motor housing using a damp cloth.
●
Do not use any abrasive or solvent-based cleaner.
Protecting the environment
Z
Separate collection. Products and batteries marked
with this symbol must not be disposed of with
normal household waste.
Products and batteries contain materials that can be
recovered or recycled reducing the demand for raw materials.
Please recycle electrical products and batteries according to
local provisions. Further information is available at
www.2helpU.com
Technical data
SFMCD700
Voltage
V
DC
18V
No-load speed
Min
-1
0-350/0-1500
Max. torque
Nm
50
Chuck capacity
mm
13
Max Drilling capacity
Steel/wood
/
masonry
mm
13/35/13
Weight
kg
1.2
Charger
SFMCB11
SFMCB12
SFMCB14
Input Voltage
V
AC
230
230
230
Output Voltage
V
DC
18
18
18
Current
A
1.25
2
4
Battery
SFMCB201 SFMCB202
SFMCB204 SFMCB206
Voltage
V
DC
18
18
18
18
Capacity
Ah
1.5
2.0
4.0
6.0
Type
Li-Ion
Li-Ion
Li-Ion
Li-Ion
Level of sound pressure according to EN62841:
Sound pressure (L
pA
) 70.0 dB(A), uncertainty (K) 5 dB(A)
Sound power (L
WA
) 81.0 dB(A), uncertainty (K) 5 dB(A)
Vibration total values (triax vector sum) according to EN62841:
Drilling into metal (a
h, D
) 1.2 m/s
2
, uncertainty (K) 1.5 m/s
2
Содержание FATMAX V20 LITHIUM ION SFMCD700
Страница 1: ...www stanley eu SFMCD700 1 7 8 2 6 5 3 4 ...
Страница 3: ...3 6 9 9b 9a A 6 6a B 6 C 6 7 D 10 11 12 E 10 F ...
Страница 97: ...97 ...
Страница 98: ...98 ...
Страница 99: ...99 ...