Problem
Cause
Solution
Fluid gets too hot.
Circuit relief set too low.
Adjust relief valve to 2100-2250/145-
155 bar.
Too much fluid going through tool.
Adjust flow for 6 GPM/23 LPM
maximum.
Circuit has contaminants that
have caused wear and high heat
generation.
Replace worn pump and valves. Install
a large clean filter and keep the fluid
clean.
Gear shift knob turns hard.
Oil leak at motor shaft seal into
gearbox causes high pressure in
gearbox.
See your authorized service dealer for
repair.
No gearshift function.
Shifter pin worn or broken.
See your authorized service dealer for
repair.
Water leaking out of shaft.
Output shaft seals worn.
See your authorized service dealer for
repair.
Water pressure too high. Seal
damaged.
Maximum water pressure 60 psi/4 bar.
Replace seals.
ANCHOR STAND TROUBLESHOOTING
Symptom
Cause
Solution
The Anchor Stand will not hold a
vacuum.
Debris under the base gasket is
preventing a good seal.
Clean the surface on which the
gasket must seal.
Debris between the base gasket
and the base.
Clean the base surface.
The gasket is worn out or damaged. Replace.
The slot gasket will not seal.
Inspect. Clean or replace.
The vacuum release button is
leaking.
Inspect. Clean or replace.
Leveling screw(s) set too far down. Retract the screws to allow the
base gasket to seal.
Vacuum leak in the line between the
base and vacuum pump.
Inspect and seal as required.
Excessive play between the
carriage and mast.
Normal wear of the guide bushings. Adjust the guide bushings.
Excessive play between the mast
and the base.
Pivot block capscrews are loose.
Tighten the capscrews to just snug
to remove play.
TROUBLESHOOTING