IMPORTANT: DURING CLEANING CARE MUST BE
TAKEN NOT TO DAMAGE THE INSULATING
BOARDS.
Boiler access is made by opening the top left hand control
door.
1.
Remove two cooker control knobs.
2.
Remove 2 retaining screws and lift the control panel
free of the aperture.
3.
Remove 2 retaining nuts and withdraw burner access
panel.
4.
The baffles are assembled in two stacks, it maybe
necessary to slightly lift the top stack of baffles and
withdraw bottom baffle stack first, then withdraw the
second stack of baffles.
Each heat exchanger has 3 rows of baffles.
5.
Ensure baffles and flueways are clear of debris and re-
fit baffle stacks as illustrated in Fig 8.
NOTE:
One baffle configuration for all three models.
6.
Carefully vacuum any debris that has fallen into the
burner chamber.
7.
Re-assemble in reverse order.
7
HEAT EXCHANGER CLEANING
Cleaning
FIG. 5
FIG. 7
DESN 514816
DESN 514818
FIG. 6
DESN 514850
FIG. 8
DESN 514819
Содержание Alpha 120
Страница 19: ...Replacement of parts Electrical controls FIG 34 DESN 514830 19 ...
Страница 26: ...26 FIG 43 Fault Finding ...
Страница 30: ...30 Fault Finding ...
Страница 31: ...Fault Finding 31 ...
Страница 32: ...32 Fault Finding ...
Страница 33: ...33 Fault Finding ...
Страница 35: ...35 ...