1. Pull the supply cord from the inside of the pole into the luminaire and insert the supply cable loosing the  
    cable gland. 
    After inserting, tighten the cable gland with the following torque. 
    Failure to do so may result in dropped electric wires, electric shock, and electric leakage. 
   

Tightening torque: 2.2~3.0N・m 

 
2. Please use the 3-core cable of 60245 IEC 57 for the supply cable and be sure to crimp the terminal with  
    insulation cover to the tip. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3. Loosen the screw on the terminal block cover and remove the cover. 
 
4. Connect the supply wire securely to the terminal block. 
    Failure to do so may result in dropped electric wires, electric shock, and electric leakage. 

    Tightening torque: 0.6N・m 

 
 
 
 
 
 
 
 
 
 
 

Top cover 

2. Open the top cover. 
    Please push down the top cover, 
    and remove the spring in the direction of arrow ②. 

Installation of luminaire 

Wiring 

45~55 

60245 IEC 57 
3×1.0mm

terminal with insulation cove 

Supply cable 

7.5 Max 

Φ6~11 

3/5 

Spring 

① 

② 

Cable gland 

Supply cable 

terminal block cover 