![Standart SNL Series Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/standart/snl-series/snl-series_instructions-for-installation-operation-maintenance_1359286019.webp)
ATTENTION
13
F
Z
F
X
F
Y
F
Z
F
X
F
Y
40-125
40-160
40-200
50-125
50-160
50-200
50-250
65-125
65-160
65-200
65-250
65-315
80-125
80-160
80-200
80-250
80-315
100-160
100-200
100-250
100-315
100-400
125-200
125-250
125-315
125-400
125-450
150-250
150-315
150-400
200-315
200-400
Type
DN
40
50
65
80
100
125
150
200
Fx
410
560
710
840
1100
1400
1700
2300
Mz
200
250
300
330
380
500
630
900
Mb
700
780
850
930
1100
1300
1600
2200
Fy
380
510
640
770
1000
1300
1500
2000
Fz
470
620
790
940
1300
1600
1900
2500
Fb
730
980
1200
1500
2000
2500
2900
3900
Mx
280
330
380
400
480
630
780
1100
My
400
450
500
550
630
800
1000
1400
K- PERMISSIBLE FORCES AND MOMENTS AT THE PUMP FLANGES
* Forces in Newton [N], moments in Newton x Meter [N.m].
** Values are applicable for casing material “Grey Cast Iron (EN-JL-250 / GG25)”.
Higher values are permissible for steel construction pumps.
The real forces and moments which affects on flanges must be
smaller than the values given in the table.