Standard Pump SPFP05 Скачать руководство пользователя страница 10

spfp05sm-rev0

516

7

 • Model SPFP05 Food Processing

www

.

standardpump

.

com

Composite Repair Parts Drawing

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

24

25

26

27

28

29

30

31

32

33

34

35

35

36

36

37

22

21

FUSION DIAPHRAGM ASSEMBLY

22

23

21

24

25

PTFE 2-PIECE DIAPHRAGM ASSEMBLY

Torque Setting:

60 in-lbs.

Torque Setting:

70 in-lbs.

Torque Setting:

60 in-lbs.

Torque Setting:

90 in-lbs.

Torque Setting:

90 in-lbs.

Torque Setting:

30 in-lbs.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

24

25

26

27

28

29

30

31

32

33

34

35

35

36

36

37

22

21

FUSION DIAPHRAGM ASSEMBLY

22

23

21

24

25

PTFE 2-PIECE DIAPHRAGM ASSEMBLY

Torque Setting:

60 in-lbs.

Torque Setting:

70 in-lbs.

Torque Setting:

60 in-lbs.

Torque Setting:

90 in-lbs.

Torque Setting:

90 in-lbs.

Torque Setting:

30 in-lbs.

General Model Specific

3: EXP

 VIEW

Содержание SPFP05

Страница 1: ...72 18 26 RUBBER FOOT Standard PumpSPFP05 Models SPFP05PPT SPFP05PPS SPFP05PPP STANDARD PUMP INC 1610 Satellite Blvd Suite D Duluth Ga 30097 Phone 770 307 1003 www standardpump com 1 PUMP SPECS 2 INSTA...

Страница 2: ...r loosening caused by gasket creep Retighten loose fasteners to prevent leakage Follow recommended torques stated in this manual CAUTION WARNING Nonmetallic pumps and plastic components are not UV sta...

Страница 3: ...TION 4 Principle of Pump Operation Typical Installation Guide Troubleshooting SECTION 3 EXPLODED VIEW 7 Composite Drawings Parts List Materials Code SECTION 4 CERTIFICATES 9 EC Declaration of Conformi...

Страница 4: ...M3 HR 2 3 4 4 6 8 8 13 6 12 20 4 Model SPFP05PPS 1 2 Bolted Metal FDA SANTOPRENE FITTED Flow Rate Adjustable to 0 12 gpm 45 4 lpm Port Size Suction 1 Tri Clamp Discharge 1 Tri Clamp Air Inlet 3 8 NPT...

Страница 5: ...rials can be operated Temperatures coupled with pressure affect the longevity of diaphragm pump components Maximum life should not be expected at the extreme limits of the temperature ranges Metals St...

Страница 6: ...an be requested if physical dimensions are needed Dimensional Drawings 98 24 96 7 45 189 13 9 42 239 27 1 98 50 29 O D TRI CLAMP SUCTION PORT 1 98 50 29 O D TRI CLAMP DISCHARGE PORT 3 8 AIR INLET 25 6...

Страница 7: ...re P4 to push the fluid through the suction piping and across the suction side check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or...

Страница 8: ...ter in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve can be opened to...

Страница 9: ...lds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designed for 1 1 pressure ratio at zero flow Does not app...

Страница 10: ...tting 60 in lbs Torque Setting 70 in lbs Torque Setting 60 in lbs Torque Setting 90 in lbs Torque Setting 30 in lbs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 24 25 26 27 28 29 30 32 3 3...

Страница 11: ...des Item 16 16 6 Pilot Valve Sleeve O Rings 17 2 Shaft Pilot Retainer 18 4 Retainer Screw 19 1 Muffler Diaphragm Assembly Elastomers Item Qty Description Part Number SPFP05PPS SPFP05PPP SPFP05PPT FDAS...

Страница 12: ...TUNG DER VORSCHRIFTEN DICHIARAZIONE DI CONFORMIT CONFORMITEITSVERKLARING DEKLARATION OM VERENSST MMELSE EF OVERENSSTEMMELSESERKL RING VAATIMUSTENMUKAISUUSVAKUUTUS SAMSVARSERKL RING DECLARA AO DE CONFO...

Страница 13: ...d Contact Materials Signature of authorized person Revision Level B Printed name of authorized person Chris Murphy Director of Operations October 13 2015 Date of issue September 11 2013 Title Date of...

Отзывы: