Standard Pump SP3A15NPT Скачать руководство пользователя страница 4

sp3a15nptsm-rev0

1

 • Model SP3A15NPT

www

.

standardpump

.

com

Performance

SP3A15NPT 1 1/2" Sanitary Pump 

PTFE Fitted

Flow Rate

Adjustable to   .  .  .  .  .  .  .  . 0-51 gpm (193 lpm)

Port Size

 Suction  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1 1/2" Tri-Clamp

 Discharge .  .  .  .  .  .  .  .  .  .  .  .  .  . 1 1/2" Tri-Clamp 

Air Inlet

 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1/2" NPT

Air Exhaust

 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3/4" NPT

Suction Lift

 Dry   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .15' (4 .57 m)

 Wet .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .25' (7 .62 m)

Max Solid Size

 (Diameter)

 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3/8" (9 .5 mm)

Max Noise Level

 .  .  .  .  .  .  .  .  .  .  .  . 101 dB(A)

Shipping Weights

Stainless Steel  .  .  .  .  .  .  .  .  .  .  .  . 75 lbs (34 kg)

NOTE: Performance based on the following: PTFE fitted pump, flooded suction, water at ambient 

conditions. The use of other materials and varying hydraulic conditions may result in deviations in 

excess of 5%.

Discharge Head in PSI

0

140

120

100

80

60

40

20

Capacity in Liters Per Minute

Capacity in U.S. Gallons Per Minute

Displacement Per Stroke, 0.11 Gal. (0.42 L)

AIR CONSUMPTION IN SCFM

AIR PRESSURE IN PSI

 SCFM M3/HR

 10 

17

 20 

34

 30 

51

 40 

68

 50 

85

 60 

101.9

 70 

118.9

0

20

10

10 2030

40

50

60

70

40

30

50

60

Meters Feet

0

0

40

80

120

160

200

240

280

320

10

20

30

40

50

60

80

90

70

0

1

2

3

4

5

6

7

8

9

10

BAR

50

100

150

200

Materials

Material Profile:

Operating 

Temperatures:

Max.

Min.

Virgin PTFE:

 (PFA/TFE) Chemically inert, virtually impervious . 

Very few chemicals are known to chemically react with PTFE; 

molten alkali metals, turbulent liquid or gaseous fluorine and 

a few fluoro-chemicals such as chlorine trifluoride or oxygen 

difluoride which readily liberate free fluorine at elevated  

temperatures .

220

°

F

104

°

C

-35

°

F

-37

°

C

Maximum and Minimum Temperatures are the limits for which these materials can be operated. 

Temperatures coupled with pressure affect the longevity of diaphragm pump components. 

Maximum life should not be expected at the extreme limits of the temperature ranges.

Metals:

Stainless Steel: 

Equal to or exceeding ASTM specification A743 CF-8M for corrosion 

resistant iron chromium, iron chromium nickel and nickel based alloy castings for  

general applicaitons . Commonly referred to as 316 Stainless Steel in the pump industry .

CAUTION! 

Operating temperature limitations are as follows:

1: PUMP

 SPECS

Содержание SP3A15NPT

Страница 1: ...rd Pump STANDARD PUMP INC 1610 Satellite Blvd Suite D Duluth Ga 30097 Phone 770 307 1003 www standardpump com SP3A15NPT 1 1 2 3 A Certified with Metallic Center Section 1 PUMP SPECS 2 INSTAL OP 3 EXP...

Страница 2: ...r loosening caused by gasket creep Retighten loose fasteners to prevent leakage Follow recommended torques stated in this manual CAUTION WARNING Nonmetallic pumps and plastic components are not UV sta...

Страница 3: ...mensional Drawings SECTION 2 INSTALLATION OPERATION 3 Principle of Pump Operation Typical Installation Guide Troubleshooting SECTION 3 EXPLODED VIEW 7 Composite Drawings Parts List SECTION 4 CERTIFICA...

Страница 4: ...Meters Feet 0 0 40 80 120 160 200 240 280 320 10 20 30 40 50 60 80 90 70 0 1 2 3 4 5 6 7 8 9 10 BAR 50 100 150 200 Materials Material Profile Operating Temperatures Max Min Virgin PTFE PFA TFE Chemic...

Страница 5: ...D DRAWING CAN BE REQUESTED IF PHYSICAL DIMENSIONS ARE NEEDED A UPDATED TO CURRENT DESIGN MAV 10 12 10 REV REVISION CHG DATE 6 7 8 8 7 6 5 4 D C B A 9 80 72 29 80 31 55 1 98 O D DISCHARGE TRI CLAMP FLA...

Страница 6: ...check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically pu...

Страница 7: ...the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve can be opened to incre...

Страница 8: ...allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designed for 1 1 pressure ratio at zero flow Does not apply to h...

Страница 9: ...line to the pump inlet Maintain the flow of steam through the pump for at least five minutes after the temperature at the outlet has reached 200 F 94 C Hot water may also be used Pump water that is m...

Страница 10: ...UPDATED TO NEW MANUAL FORMAT MAV 6 5 12 REV REVISION CHG DATE THIS IS A PROPRIETARY DOCUMENT DO NOT REPRODUCE OR DISCLOSE WITHOUT THE EXPRESS WRITTEN PERMISSION OF WARREN RUPP INC DESCRIPTION DRAWING...

Страница 11: ...ssembly Elastomers Item Qty Description Part Number 23 1 Main Shaft 25 2 Diaphragm 29 4 Valve Ball 30 4 Manifold Tee Seal 31 4 Manifold Elbow Seal Wet End Assembly Item Qty Description Part Number 32...

Страница 12: ...TUNG DER VORSCHRIFTEN DICHIARAZIONE DI CONFORMIT CONFORMITEITSVERKLARING DEKLARATION OM VERENSST MMELSE EF OVERENSSTEMMELSESERKL RING VAATIMUSTENMUKAISUUSVAKUUTUS SAMSVARSERKL RING DECLARA AO DE CONFO...

Страница 13: ...fully with the 3 A Sanitary Standards designated Legal responsibility for compliance is solely that of the holder of this Certificate of Authorization and 3 A Sanitary Standards Inc does not warrant...

Отзывы: