background image

Owner’s Manual

MD150 User Manual

Page 13

7 Specifications

Power Supply
• 10.7 to 16.6 VDC, 90 mA nominal, 110 mA with

backlight on.

Operating temperature
• 32° to 113°F (0° to 45°C)

Size of display
• 4.4 x 4.4 x 1" (112 x 112 x 24mm), overall

depth 1.4" (35mm) behind panel.

Display type.
• Twisted Nematic (TN) gray background.

Illumination
• Red LED switchable from key pad.

RF interference
• Less than 6 dB maximum quieting on any

marine radio channel with 3 dB gain antenna
within 1 meter of instrument display head
(European EC specifications).

Depth
• 1 to 130 meters or 3 to 400ft.

Alarms
• Depth shallow and deep.

Display unit selection
• Feet, meters or fathoms, key pad selectable.

Alarm
• Shallow and deep, water. Audio and LCD flag.

• Transducer

200 kHz, 600 ohm, 1500pF parallel
capacitance.

Boat speed
• 0 to 50 knots, 0 to 90 kph, 0 to 60 Mph

(depending on transducer type). User
selectable to display in 0.1 or 0.01 increments.

Speed units and resolution
• 0.0 to 19.9 and then 20 to 50 in knots, MPH or

KPH.

Average speed
• User selectable to 50 knots, resets to zero via

key pad or at power down.

Maximum speed
• Records max. speed to 50 knots. Reset to

zero via key pad or at power down.

Trip log
• 0 to 1999 units key pad resettable.

Total log
• 0 to 1999 units key pad resettable.

Keel Offset
• Keel or waterline, ±9.9 ft, ±1.6 fathoms or ±3.0

meters, user resettable. Allows for display of
depth below keel or waterline.

Trend Indication
• Arrows indicate increasing or decreasing depth

and speed trends.

Timers
• user configurable count down timers with

audible alarms, 0 to 19:59 hours count up
elapsed time.

Sea Temperature
• 32.0° to 99.9°F (0.0° to 37.7°C) 10 kOhm at

25°C. Tenths of a degree are displayed.

Sea Temperature Sensor Type
• 10 kOhm NTC at 77°F (25°C)

NMEA Output data
• VHW, VLW, MTW, DBT, DPT.

Transducer input cables
• Phono connector for depth, 4 pin Fuji for

speed/temp transducer. 3 conductor cable for
NMEA and power.

Your Digital Multi data instrument is designed for years of trouble free operation assuming proper installation
and care are provided. Following the operation and installation guidelines in this manual should ensure
optimum performance of the instrument. In the unlikely event that the instrument shall fail to perform or
shall need servicing, contact:-

6 Maintenance

Standard Horizon
Factory Repair Facility
115 North Wright Brothers Drive
Salt Lake City, UT 84116

Telephone number (800) 366-4566
Fax number (801) 359-4122

Содержание MD150

Страница 1: ...MD150 Digital Multi Data Instrument Owner sManual Marine Division of Vertex Standard ...

Страница 2: ... defective This limited warranty does not extend to any product which has been subjected to misuse neglect accident improper installation or subject to use in violation of the maintenance or operating instructions if any furnished by STANDARD HORIZON nor does this warranty extend to products on which the serial number has been removed defaced or changed STANDARD HORIZON reserves the right to make ...

Страница 3: ...ctions 8 5 Operation 8 5 2 Select Depth Units 8 5 3 The Depth Alarms 9 5 3 1 Setting Alarms 9 5 3 2 Set Shallow Alarm 9 5 3 3 Set Deep Alarm 9 5 4 Select Temperature Units 9 5 5 Timer Functions 9 5 5 1 Elapsed Timer 9 5 5 2 Count Down Timers 10 5 3 Select Speed Log Units 10 5 7 Reset Log 10 5 8 Reset Total Log 10 5 10 Reset Average Speed 10 5 11 Backlighting On Off 10 5 12 Secondary Functions 11 5...

Страница 4: ...dback to indicate when a key is pressed All functions are controlled entirely by these four keys 1 3 Rear panel The rear panel contains a Fuji 4 pin connector for connection to the speed transducer and an RCA phono connector for connection to the depth transducer It also contains red and black wires for connection to the power supply and a blue wire for NMEA output for interfacing with 150 series ...

Страница 5: ...ng ability of the gasket is damaged 3 Accessories 3 1 Optional SIA51 Transom Mount Impeller with 30 foot cable SIA53 Thru hull Speed Impeller EX345 15 foot Impeller Extension Cable EX345D 15 foot Transducer Extension Cable DST50 2 inch low profile Transducer DST51 Transom Mount Transducer DST52 Bronze Long Stem Thru hull Transducer DST53 2 inch Bronze low profile Transducer DST55 In hull Depth Tra...

Страница 6: ...e as short as possible Connect the red wire to the positive supply via a 1 amp fuse or a 1 amp circuit breaker Connect the black wire to the electrical ground A 1 amp fuse will provide protection for up to five 100 series instruments Connect the 4 pin Fuji connector to the speed and temperature transducer cable connector Extension cables are available if the transducer cable is too short If you ar...

Страница 7: ...impellers and transducers Specific installation instructions are supplied with each impeller or transducer 4 5 2 In Hull Installation Transducer installation inside a solid fiberglass hull may degrade performance of depth sounder Therefore this type of installation is not preferred over thru hull and transom installations Should the user desire to perform an in hull installation perform the follow...

Страница 8: ...power down 5 2 Select Depth Units When the top section of the display is indicating depth press and hold the key for three seconds The new unit of measure will be displayed for three seconds Alternately when the bottom section of the display is indicating depth press and hold the key for three seconds The new unit of measure will be displayed for three seconds Depth units can be selected in the fo...

Страница 9: ...ons All timer functions are displayed on the lower section of the display 5 5 1 Elapsed Timer The elapsed timer will record time from power up Time is displayed in hours and minutes up to 99 hours and 59 minutes Press the key to show elapsed time 5 3 The Depth Alarms The shallow water alarm sounds when the depth falls below the selected value The deep water alarm sounds when the depth exceeds the ...

Страница 10: ...hold the key for three seconds The new unit of measure will be displayed for three seconds Alternately when the bottom section of the display is indicating speed press and hold the key for three seconds The new unit of measure will be displayed for three seconds Note When changing speed distance units the log totals are re calculated to show the same distance in the new units 5 7 Reset Log With th...

Страница 11: ...of water temperature and speed display options of 1 10th or 1 100th units or or or or EXIT 5 13 Calibration Procedures Note If the speed and depth readings flash this indicates that the calibration values have been lost To correct this check the depth units alarm values keel offset speed units and the speed calibration PRESS HOLD FOR 3 SECONDS TO ENTER SECONDARY MODE KEEL OFFSET PRESS BOTH KEYS TO...

Страница 12: ...et The MD150 will normally display the depth of water below the face of the transducer You may introduce a keel offset to display the depth of water below the keel A positive value may be entered to display the depth of water from the water surface to the bottom This is often called waterline offset Follow the Secondary Functions chart to reach Keel Offset mode Use the or key to set the required v...

Страница 13: ...o 50 knots Reset to zero via key pad or at power down Trip log 0 to 1999 units key pad resettable Total log 0 to 1999 units key pad resettable Keel Offset Keel or waterline 9 9 ft 1 6 fathoms or 3 0 meters user resettable Allows for display of depth below keel or waterline Trend Indication Arrows indicate increasing or decreasing depth and speed trends Timers user configurable count down timers wi...

Страница 14: ...ve terminal of the ignition coil b Add alternator whine filter to alternator c Replace spark plug with resistive type 6 No or inaccurate temperature reading Remove inspect and clean transducer if needed Measure resistance between pins 1 and 4 on connector Transducer is defective if shorted or open a Check calibration b Check for break in cable 7 Speed cable is not long enough Use EX345 optional ca...

Страница 15: ...Owner s Manual MD150 User Manual Page 15 ...

Страница 16: ...17210 Edwards Road Cerrtios CA 90703 Telephone 562 404 2700 STANDARD HORIZON ALL RIGHTS RESERVED PRINTED IN NEW ZEALAND FEBRUARY 2001 M32385104A 1950751A MN000017 Marine Division of Vertex Standard ...

Отзывы: