OPERATIONAL INSTRUCTIONS

10

GENERAL PRECAUTIONS

Use the lowe st holes in the 

PIVOT ARMS(5)

 until you be come familiar with the 

Gravity Inversion

Therapy Table.

Do not use the 

Gravity Inversion Therapy Table

 alone.  Always have a helper available in case assistance

is needed in recovering from the decline position.

Make sure that the 

HEEL HOLDERS(12)

 and 

FOAM PADS(31)

 are holding your feet securely.

Make sure that the 

HEIGHT ADJUSTMENT BEAM(6)

 is properly set for your height.

Make sure that the 

HEIGHT ADJUSTMENT BEAM(6)

 is held se curely by both the 

LARGE SPRING

PIN(18)

 and the 

LOCKING KNOB(19).

Make sure that there is enough room for the bed to rotate completely.

1.

2.

3.

4.

5.

6.

THE HANDLEBARS

For added convenience, and safety, a set of 

HANDLEBARS

 has been a dded to the 

Gravity Inversion

Therapy Table.

  These 

HANDLEBARS

 are located at the top of the 

REAR FRAME(2).

  The 

HANDLEBARS

are to help you return to the upright position from a

ny degree of inversion.  If you wish to return to the upright

position, and the bed is moving too slowly, or not moving at all, simply grab the 

HANDLEBARS

 and pull on

them until you return to the upright position.

HEIGHT ADJUSTMENT

The 

Gravity Inversion Therapy Table

 is a very sensitive balance device.  It responds to very slight changes

in weight distribution.  It is very important to make sure that the height adjustment is set properly.  Use the

following procedure to set the height adjustment and balance the 

Gravity Inversion Therapy Table.

Adjust the 

NYLON STRAPS

 to re strict

movement to a pproximately 15 degree s

beyond the horizontal position.  The

nylon straps

 

should not allow the 

Gravity

Inversion Therapy Table

 to go into the full

inversion position while you are setting the

height adjustment.

Loosen the 

LOCKING KNOB(19)

 under the

MAIN FRAME(4).

Pull the 

LARGE SPRING PIN(18)

 and use

the 

SCALE DECAL(16)

 to set the 

HEIGHT

ADJUSTMENT BEAM(6).

Tighten the 

LOCKING KNOB(19).

Mount the machine.

Lock your ankles into the 

HEEL HOLDERS

(12)

 and 

FOAM PADS(31).

Lie back with your hands at your sides.

Slowly raise your hands to your chest.

If your feet are higher tha n your he ad,

dismount and try a taller setting.  If you do

not rotate to a position close to level,

dismount and try a shorter setting.

1.

2.

3.

4.

5.

6.

7.

8.

9.

The 

Gravity Inversion Therapy Table

 should return to the upright position when your hands are

below your waist.  If it does not, use a taller setting.

Verify that adequate head clearance is available between the user's hea d and the floor bef ore

using this inversion table. This is especially important for tall users.

NOTE:

1.

2.

Handlebars

Содержание 55-1532A

Страница 1: ...equi pment Serious bodily injury can occur if this equipment is not a ssembled and used corre ctly Serious bodily injury can also occur if all in structions are not followed Kee p others a nd pets awa...

Страница 2: ...e than 250 lbs The Gravity Inversion Therapy Table should not be used by persons over 6 feet 6 inches tall It is recommended that you place this exercise equipment on an equipment mat Use the Gravity...

Страница 3: ...ody into shape and on your way to achieving a happier and healthier lifestyle CALL US FIRST 3 Should you have any questions please call our Customer Service Department toll free number 1 800 375 7520...

Страница 4: ...rench Although Stamina manufactures its products with the finest materials and uses the highest standards of manufacturing occasionally a part that doe s not fit is the incorrect size or is otherwise...

Страница 5: ...check the length of the bolts and screws NOTICE The length of all bolts a nd screws except those with flat heads is measured from below the he ad to the end of the bolt or screw Flat head bolts a nd...

Страница 6: ...ucts com 6 STEP 1 Unfold the BASE ASSEMBLY to a n upright position by moving the FRONT FRAME 1 away from the REAR FRAME 2 Then push down on the middle of the two FOLDING LINKAGES 3 until they are full...

Страница 7: ...osition the MAIN FRAME 4 at three different heights The lowest hole will allow the le ast amount of inversion a ngle The top hole will allow the greatest amount of inversion angle CAUTION STEP 4 Attac...

Страница 8: ...USTABLE INSTEP FRAME 7 completely into the HEIGHT ADJUSTMENT BEAM 6 Place a WASHER M6 45 onto the HEX BOLT M6x1x47mm 40 then insert the bolt the hal fway through the s quare tube on theHEIGHT ADJUSTME...

Страница 9: ...27 onto the loop on the back of the MAIN FRAME 4 Hook the end of the BUCKLE STRAP 28 onto the loop on the FRONT FRAME 1 NOTE A C B BUCKLE Do not use the Gravity Inversion Therapy Table until you have...

Страница 10: ...Table is a very sen sitive balance device It re sponds to very slight cha nges in weight distribution It is very important to make sure that the height adjustment is set properly Use the following pr...

Страница 11: ...n table will be as far back as it can go As you get more comf ortable with the use rock the bed slowly by moving your arms up a nd down slowly A gentle swinging motion will alternately put your spine...

Страница 12: ...day SUGGESTIONS FOR USE 1 2 3 4 5 A B C LOCKING THE BED When the inversion table rotates past the vertical inverted position the bed be comes locked and will not return to the upright position in the...

Страница 13: ...ng up on theMAIN FRAME 4 until the PIVOT ARMS 5 come out of the slots located at the top of theREAR FRAME 2 Make sure the NYLON STRAP is not attached to the MAIN FRAME 4 before attempting to remove it...

Страница 14: ...PRODUCT PARTS DRAWING BACK FRONT 14...

Страница 15: ...2 25 Bumper 1 26 Hook 2 27 Nylon Strap 1 28 Buckle Strap 1 29 Hollow Cap 1 30 Stand 4 31 Foam Pad 2 32 Dome Plug 22 2mm 4 33 Round Plug 31 8mm 2 34 Square Plug 33 4mm x 33 4mm 1 35 Square Plug 38mm x...

Страница 16: ...PURCHASER This limited warranty is not transferable IF ANY PART OF THE PRODUCT IS NOT IN COMPLIANCE WITH THIS LIMITED WARRANTY OR ANY IMPLIED WARRANTY THE REMEDY OF REPAIR OR REPLACEMENT IS THE EXCLUS...

Страница 17: ...NOTES 17...

Страница 18: ...800 375 7520 in the U S from 7 30 A M 5 00 P M Central Time Monday Thursday and 8 00 A M 3 00 P M on Friday or f ill out the fax sheet ordering f orm below and fax it to 417 889 8064 Our Customer Serv...