1.  While the unit is unplugged and cooled down, unscrew the nozzle at 

the very front of the unit and clean out debris with vinegar and a pipe 

cleaner, making sure that the hole is free of clogs.

2.  Empty all fog fluid from the machine. Add cleaning solution to the tank. 

Plug the unit in and let it warm up.

3.  Run the unit in a well-ventilated area, until the tank is empty.

4.  Replace the nozzle.

5.  Cleaning is now completed, refill with fog liquid.

6. Troubleshooting

If you experience low output, pump noise or no output at all, unplug the 

unit immediately. Check the fluid level, the external fuse, remote connec

-

tion, and power from the wall outlet. If all of the above appears to be O.K., 

plug the unit in again. If fog does not come out after holding the remote 

button down for 30 seconds, check the hose attached to the tank to make 

sure there is fluid going through the hose. If you are unable to determine 

the cause of the problem, do not simply continue pushing the remote but-

ton, as this may damage the unit. Return the machine to your dealer.

WARNING!

Never block ventilation holes!

 

X

Never touch the unit when it‘s hot!

 

X

No user serviceable parts inside. Refer to your Fogger dealer 

 

X

or other qualified service personnel.

7. Specification

Rating Voltage: 

 

220-240V~/50Hz 

Power Consumption:   

700W

 

Fuse:   

 

 

5A/250V 

Tank capacity:  

 

1,0 Liter

 

Dimensions:   

 

33 x 16 x 13cm

 

Weight: 

 

 

ca. 4 kg

As we continuously strive to improve our products, all specifications and 

appearance are subject to change without prior notice.