- 5 -
1. While the unit is unplugged and cooled down, unscrew the nozzle at
the very front of the unit and clean out debris with vinegar and a pipe
cleaner, making sure that the hole is free of clogs.
2. Empty all fog fluid from the machine. Add cleaning solution to the tank.
Plug the unit in and let it warm up.
3. Run the unit in a well-ventilated area, until the tank is empty.
4. Replace the nozzle.
5. Cleaning is now completed, refill with fog liquid.
6. Troubleshooting
If you experience low output, pump noise or no output at all, unplug the
unit immediately. Check the fluid level, the external fuse, remote connec
-
tion, and power from the wall outlet. If all of the above appears to be O.K.,
plug the unit in again. If fog does not come out after holding the remote
button down for 30 seconds, check the hose attached to the tank to make
sure there is fluid going through the hose. If you are unable to determine
the cause of the problem, do not simply continue pushing the remote but-
ton, as this may damage the unit. Return the machine to your dealer.
WARNING!
Never block ventilation holes!
X
Never touch the unit when it‘s hot!
X
No user serviceable parts inside. Refer to your Fogger dealer
X
or other qualified service personnel.
7. Specification
Rating Voltage:
220-240V~/50Hz
Power Consumption:
700W
Fuse:
5A/250V
Tank capacity:
1,0 Liter
Dimensions:
33 x 16 x 13cm
Weight:
ca. 4 kg
As we continuously strive to improve our products, all specifications and
appearance are subject to change without prior notice.
Keep this manual for future reference.