Proceed as follows to display the channel values:
1.
Open the menu
‘Unit Setup’
,
‘Channel 1= 68’
(see menu overview).
2.
Confirm with the
[Menu]
button.
ð
The channel number display flashes.
3.
Select the desired channel with the navigation buttons or .
4.
Press the
[Menu]
button to exit the menu.
Open the menu
‘Unit Status’
,
‘Unit Temp=34Deg’
to display the temperature of the individual
blocks (see menu overview). Select the desired block with the navigation buttons or .
Above a temperature of 45 °C, the internal fans will be switched on. The fan power will be
increased continuously up to 100 % to a temperature of 65 °C. Above a temperature of 95 °C,
the over-temperature protection responses and turns the corresponding block off. Then the
display shows
‘L…Overheat | Unit Overheated’
. Once the temperature has dropped back below
80 °C, the block is automatically reconnected.