Contact Heart Rate Testing - Gauntlet
Contact heart rate is not
working on the Gauntlet.
Make sure there are no loose
connections in the contact
heart rate system.
Check
Connections
Are the cables
connected?
Yes
No
Connect the
cables and test the
contact heart rate.
Is the heart
rate working?
Heart rate is
operational.
Yes
Verify that the
heart rate cables
are connected to
the heart rate
plates.
Perform a
Continuity
Check on
Cables and
Plates.
No
All cables have
continuity?
Reconnect all
cables and test
contact heart rate.
Is the heart
rate working?
It is possible that
the cable is not
connected to the
plate.
Check
Connections
at the Heart
Rate Plates
No
All cables have
continuity?
Yes
Yes
Replace the contact heart
rate cable (PN: 050-0324)
No
Yes
There may be a
short in the
system.
Ensure there
are no shorts
in the system.
No
Are there any
shorts?
Replace the
console
No
Yes
Last revised 10/5/15