222936 / YL6060300020
2018-04-13·BA00·III·en·01
Mounting and installation
19
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Explosion Proof Combination Signal -
110 dB (A) / 5 Joule
Series YL60
7.2.6 Sound tone selection
• For signal tone selection and its switch positions refer to the table below.
• Check if the correct switch positions of the selected signal tones have been selected.
Tone table
Tone
no.
Version
Frequency
Sound
selection
switch
12345
(ON = 1)
Repeti
-
tion rate
(sec)
Special application
Tone
01
Alternate two-tone
800-1000
11111
0.5
Fire alarms -
Level crossing
Tone
02
Alternate two-tone
2500-3100
01111
0.5
Security alarms
Tone
03
Alternate fast two-tone
800-1000
10111
0.25
Increased urgency -
Level crossing
Tone
04
Alternate fast two-tone
2500-3100
00111
0.25
Security deterrent
Tone
05
Alternate two-tone
440-554
11011
0.4/0.1
AFNOR, France
Tone
06
Alternate two-tone
430-470
01011
1.0
Tone
07
Alternate very fast
two-tone
800-1000
10011
0.13
Tone
08
Alternate very fast
two-tone
2500-3200
00011
0.07
Tone
09
Alternate two-tone
440-554
11101
2.0
Turn out, Sweden
(SS 031711)
Tone
10
Continuous tone
700
01101
All clear, Sweden
(SS 031711)
Tone
11
Continuous tone
1000
10101
Tone
12
Continuous tone
1000
00101
Tone
13
Continuous tone
2300
11001
Tone
14
Continuous tone
440
01001
Tone
15
Interrupted tone
1000
10001
2.0
Tone
16
Interrupted tone
420
00001
1.25
AS2220, Australia
Tone
17
Interrupted tone
1000
11110
0.5
Tone
18
Interrupted tone
2500
01110
0.25
Tone
19
Interrupted tone
2500
10110
0.5