SolConeX compact flange socket
Series 8572/15
4
Function and Device Design
4.1
Function
Application range
The flange socket 8572/15 is an incomplete piece of electrical equipment and is intended
for installation in an enclosure having type of protection "e".
5
Technical Data
DANGER
Explosion hazard due to improper use!
Non-compliance results in severe or fatal injuries.
• Use the device only in accordance with the operating conditions
described in these operating instructions.
• Use the device only for the intended purpose specified in these
operating instructions.
Explosion Protection
Global (IECEx)
Gas and dust
IECEx PTB 16.0028U
Ex db eb IIC Gb
Ex tb IIIC Db
Europe (ATEX)
Gas and dust
PTB 16 ATEX 1016 U
E
II 2 G Ex db eb IIC Gb
E
II 2 D Ex tb IIIC Db
Certifications and certificates
Certificates
IECEx, ATEX
Technical Data
Electrical data
Rated operational
voltage
max. 277 V AC / 110 V DC
Frequency
0 to 60 Hz (for frequencies > 100 Hz, reduction to 12 A required)
Voltage tolerance
-10 to +10 %
Utilization category
AC-3: 277 V / 16 A
DC-1: 110 V / 16 A
DC-13: 50 V / 16 A
Rated operational
power
Rated insulation
voltage
550 V
4 kW
220 V / 230 V / 240 V