The protective earth conductor must always be connected to the enclosure using a
cable lug (2). Place a washer (1) above and below the cable lug and secure the screw
(4) using a locking device (3).
X
Regardless of the operating voltage, connect all bare, non-energised metal parts to the
protective system.
X
The external protective earth conductor is designed to be fitted with a cable lug. The
cable must be run and fixed near to the enclosure to prevent movement of the cable.
Connecting to the mains
X
Open the enclosure.
X
Lead the connecting wires with intact external insulation jackets through the cable
entry into the terminal compartment.
X
Lay the connecting wires in the terminal compartment so that the minimum permissible
bending radii are achieved.
X
The protective earth conductor must always be connected.
X
Remove loose metal particles, dirt and traces of moisture from the terminal
compartment, if any.
X
Carefully close the enclosure after finishing the work.
X
Test the isolation according to EN 60439-1.
9
Putting into operation
Before commissioning
X
Make sure that the device is not damaged.
X
Make sure that the device is installed correctly.
X
Remove any foreign object from the device and clean the terminal compartment.
X
Check that cable entries and stopping plugs are tight.
X
Check that screws and nuts are tightly fitted.
X
Inspect cable glands for damage.
X
Control torques.
X
Make sure that unused cable entries are sealed with plugs certified according to
Directive 94/9/EC, and unused holes are sealed by stopping plugs certified according
to Directive 94/9/EC.
)
Please take the details relating to potential equalisation, earthing and
intrinsically safe circuits from the documentation of the relevant equipment.