Ammeters and voltmeters
Series 8402/6, Series 8403/6, Series 8404/6,
Series 8405/6, Series 8406/6, Series 8407/6
3.3
Residual Risks
3.3.1 Explosion Hazard
Despite the device's state-of-the-art design, explosion hazards cannot be entirely eliminated
in hazardous areas.
Perform all work steps in hazardous areas with the utmost care at all times!
Transport, store, plan, install and operate the device in compliance with the technical data
exclusively (see the "Technical data" chapter).
Possible moments of danger (residual risks) can be categorised according to the following
causes:
Mechanical damage
The device can be damaged during transport, mounting or commissioning.
This kind of damage can, for example, render the device's explosion protection partially or
fully ineffective. This may result in explosions causing serious or even fatal injury to persons
in the vicinity.
Only transport the device in special transport packaging that reliably protects the device
from external influences. Observe the ambient conditions when selecting the transport
packaging (see the "Technical data" chapter).
Do not place any load on the device.
Check the packaging and the device for damage. Report any damage to R. STAHL
immediately. Do not commission a damaged device.
Store the device in its original packaging in a dry place (with no condensation),
and make sure that it is stable and protected against the effects of vibrations and knocks.
Do not damage the device and other system components during mounting.
Improper mounting, commissioning, maintenance or cleaning
Basic work such as mounting, commissioning, maintenance or cleaning of the device
must be performed only in accordance with the applicable national regulations of the country
of use and only by qualified persons. Otherwise, the explosion protection may be rendered
ineffective. This may result in explosions causing serious or even fatal injury to persons in the
vicinity.
Have mounting, installation, commissioning and maintenance performed only by qualified
and authorised persons (see Chapter 3.2) and have acceptance carried out by a test body
(3rd party inspection).
Observe the correct mounting position, see the "Mounting and installation" chapter.
Before mounting, dismounting or setting the device, disconnect it from the power supply.
When used in Zone 1 or Zone 21, the device is to be installed in a protective enclosure or
in a cabinet with a suitable degree of protection in accordance with IEC/EN 60079-0.
An enclosure with at least an IP54 protection rating is required for use in Zone 1 and
Zone 21, as well as in safe areas.
Comply with creepage distances and clearances corresponding to IEC/EN 60079-7,
Table 1.
Do not replace the scale/scale plates for ammeters with a direct display.
Do not modify or change the device.
Repair work on the device must be performed only by R. STAHL.
Gently clean the device only with a damp cloth and without scratching, abrasive or
aggressive cleaning agents or solutions.
Never clean the device with a strong water jet, e.g. using a pressure washer.