![Stahl Tools DDSI Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/stahl-tools/ddsi/ddsi_user-manual_1357993003.webp)
Indication: .............................................LCD display
Input voltage: ........................................DC 24V
Temperature:.........................................302°F ~ 842°F (150°C ~ 450°C)
DC Plug: ...............................................0.14" x 0.05" dia. (3.5 x 1.35mm)
Dimensions: ..........................................6.69" x 0.59" x 0.67" (170 x 15 x 17mm)
Power:...................................................30W
Heating time to 572°F (300°C): ............at least 30s
Soldering tip resistance to ground: .......
2. Power Supply Selection
Before powering on, please check if the adapter meets the standards listed below.
It is recommended to use the matching power adapter DDSI (24V, 1.5A).
Input
Max
Current
Time needed for heating
Voltage
Power
Needed
up to 572°F (300°C)
12V
10W
>0.8A
180s
18V
20W
>1.0A
60s
24V
30W
>1.2A
30s
Displayed
Time
Temperature
Time Set
Temperature
Temperature
Needed
Range
Range
Standby Temp
392°
3. Operation
Default Settings
Screen display
1. Temperature setting: When connected to DC power, the screen shows
time to get into the standby temp mode. In turn, the screen shows WAIT 180
(standby time needed), WAIT TEMP 392°F (standby temp) and SLEEP 360
(sleep time needed) with 2 seconds each.
the corresponding mode. If the preset standby temp is higher than the preset
working temp, standby mode is not applicable.
Keep the iron still for 3 minutes (default setting), it will get into standby mode
and the temperature will decline to the preset standby temperature. When it is
moved, it will get into working mode automatically and the temperature will rise
to the preset temperature(572°F with default setting).
Under standby mode, it will go into sleep mode after preset time.
Note: