1. CABLE MANAGEMENT
The CHRONOS traffic light allows the cable to be routed in two ways:
1.A: from the wall to the opening at the back of the bracket [A] and then into the casing
1.B: by using the dedicated pre-hole, cut a hole in the bracket, and mount a standard PG12 cable duct [B], ensu
-
ring that the cable duct is mounted before fixing the bracket to the wall
A
B
1.A
1.B
Once the correct routing of the cable has been set, fix the bracket to the wall using the suitable screws and
screw anchors.
USEFUL ADVICE
The dimensions of the case are based on the distance from the power source, so depending on the
voltage drop, Stagnoli recommends:
00 - 50 mt: 0,5-0,75 mm
50 - 100 mt: 0,75 -1 mm
>100 mt : 1 - 1,5 mm
2. OPEN THE BOTTOM COVER
Open the bottom cover by unscrewing the 4
Phillips head screws placed on the bottom.
Route the cable coming out of the bracket
through the dedicated hole [C] and if neces-
sary through the OR ring [D].
D
C