Troubleshooting

This troubleshooting guide is meant to help solve simple problems.

If a problem occurs, carry out the steps below in sequence until a 
solution is found. Once the unit operates properly, do not carry out 

following steps. If the problem persists, refer servicing to a qualified 

technician.

Power Connected but No smoke is Emitted:

1.

Check the power supply. Plug the unit into grounded electric power
supply socket with proper voltage;

2.

LCD display is lit and check if it can operate;

3.

The control panel operation is correct;

4.

No fuse breaker is jump off, if any, please press the breaker to do

the reset action;

5.

Check to see if there is enough clean water;

6.

Check whether there is low-fog fluid;

7.

Whether the heater is in the heat (light touch the iron plate next to
the low-fog fluid tank is lukewarm );

8.

Make sure the signal cable polarity is correct and good connection;

9.

Check your DMX address setting.

10. 

Check your controller if in correct connection.

Power Connected, Fog Blasts not Smooth:

Should there be no smoke emitted, running noisily or hindered fogging, 
pull out the plug immediately.  Check if string enough clean water and 
low-fog fluid, if there is enough clean water and fluid, plug-in again; still 

persists abnormal running, and If causation is unclear, stop running to 

avoid any damage, shut down to cool it, and bring unit to your local agent 
or appointed service place for inspection, prohibit any dismantlement by 

yourself.

Содержание AQUAFOG 2500

Страница 1: ...User manual ENGLISH AQUAFOG 2500 3600 Version 1 0 AQUAFOG 2500 AQUAFOG 3600...

Страница 2: ...ion 26 CONTENTS If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Read the manual Indoor use only This s...

Страница 3: ...wer supply for your unit See your product specification label for appropriate power supply This appliance must be earthed Disconnect from electric mains power supply when not in use when filling the w...

Страница 4: ...hout user serviceable parts in the package please contact your local agent or qualified technician for servicing Without changeable structure by non qualified user please do not open the rear panel or...

Страница 5: ...manual thoroughly before operation If any abnormal running occurs stop it immediately empty the fluid and bring the done up unit recommend original box to your agent or dealer for servicing Make sure...

Страница 6: ...without any prior written notice Particular Warning The machine must keep enough water to be used normally Please do not exceed the warning water line when it is poured into the water When water is n...

Страница 7: ...l water line F LCD display G 6 Function buttons H LED Indicator of Smoke ON OFF I Smoke ON OFF Express Output Button J DMX 5 PIN XLR Input K DMX 5 PIN XLR Output L DMX 3 PIN XLR Input M DMX 3 PIN XLR...

Страница 8: ...machine packed in flight case Output by one button Additional express output button is designed to simplify the continuous fogging 5 8 minutes of first heating time 2 liter liquid tank Use of our wat...

Страница 9: ...ecial low fog fluid Figure1 B 5 Fill the clean water to the tank Figure1 C Take care not to exceed the warning water line and ensure the use of clean water When water is not enough the machine will st...

Страница 10: ...mation 5 pin XLR 3 pin XLR 1 Ground 1 Ground 1 Ground 1 Ground 2 Cold 2 Cold 2 Cold 2 Cold 3 Hot 3 Hot 3 Hot 3 Hot 4 N A 4 N A 5 N A 5 N A XLR Pin Configuration Pin 1 Ground Pin 2 Data Compliment nega...

Страница 11: ...ress UP Down 1 5 seconds can change value continuously and fast pressed UP DOWN at the same time value back to 1 FOG VAL Setting of smoke output 0 10 100 WIND VAL Setting of wind volume 10 100 WATER M...

Страница 12: ...ating again and enter the standby state FLUID SCAN ON OFF ON OFF setting of automatic inspection of fluid 1 When this function is OFF the machine cannot inspect volume of the fluid This means that the...

Страница 13: ...machine that combines the effects of smoke and water mist the specific relationship is as follows smoke water mist low fog total volume Control priority order When both DMX console and VT 1 are conne...

Страница 14: ...FF for AQUAFOG 2500 On the left shows the current water mist is ON U A B Water Mist volume for AQUAFOG 3600 On the left shows the current water mist is A B 100 V1 0 NO WATER HEATING F100 W10 U ON HEAT...

Страница 15: ...g the blue led above SMOKE ON OFF BUTTON will continue to flash After several seconds return to left icon Press Function button to select water mist VAL and setting the state of volume press UP DOWN b...

Страница 16: ...0 or 10 100 The display on left shows volume is 100 Press Function button to select water mist VAL and setting the state of volume press UP DOWN button to select the volume state ON OFF for AQUAFOG 2...

Страница 17: ...This is to avoid causing negative effect when used next time After several seconds return to left icon CLEANING F100 D52 I30 STANDBY F100 W10 U A B 8 9 Set values are automatically saved UP DOWN butt...

Страница 18: ...next time STANDBY F20 W50 U A B RUNNING F20 W50 U A B STANDBY F20 W50 U A B CLEANING F20 W50 U A B 5 7 9 8 6 The volume adjustment knob clockwise adjustment volume increases counterclockwise adjustme...

Страница 19: ...press and hold Manual button without releasing Manual fogging operation can priority to other operations 3 Release Manual to recover previous status A B C D A 1 4 stereo jack B Knob C Green LED Volume...

Страница 20: ...button to select the channel mode there are 1CH 4CH and 6CH to choose from set values are automatically saved Left display shows 6 channel mode Set values are automatically saved Then enter the DMX o...

Страница 21: ...procedure to link more low fog machines if desired whole link is daisy chain 9 Done Refer to DMX channel chart in Figure 2 make related settings Now start operating Wig Smog with DMX console Set value...

Страница 22: ...will always be cycled CH1 DMX Value Smoke ON OFF 6 255 ON 0 5 OFF CH1 CH2 CH3 CH4 DMX Value Smoke Volume DMX Value Wind Volume DMX Value Water Mist ON OFF DMX Value Smoke ON OFF 6 255 10 100 0 255 10...

Страница 23: ...e Smoke ON OFF 6 255 ON 0 5 OFF CH1 CH2 CH3 CH4 DMX Value Smoke Volume DMX Value Wind Volume DMX Value Water Mist ON OFF DMX Value Smoke ON OFF 6 255 10 100 0 255 10 100 201 255 100 A B 128 255 ON 0 5...

Страница 24: ...5 Check to see if there is enough clean water 6 Check whether there is low fog fluid 7 Whether the heater is in the heat light touch the iron plate next to the low fog fluid tank is lukewarm 8 Make su...

Страница 25: ...e machine detects that no fluid the pump will stop working Maintenance Before doing maintenance please make sure that the power is cut the power cord is unplugged and the machine itself has cooled dow...

Страница 26: ...clear all the liquid water and low fog fluid and keep the machine dry 6 Do not stack heavy objects or other items on the top of the machine to avoid damage or deformation of the machine 7 The machine...

Страница 27: ...25 Accessories Fog Conducting Hose 2 8 meters Top cover of flight case Fog Conducting Hose Adaptor AQUAFOG HOSE SET AQUAFOG CASE TOP...

Страница 28: ...Fogging Continuous Fogging Manual Fogging No Fluid Warning YES YES Low Water Shutdown YES YES Output Adjustment 0 10 100 0 10 100 Wind Adjustment 10 100 10 100 Water Mist Adjustment ON OF A 50 B 50 A...

Страница 29: ...op cover of flight case Weight kg 72KG with top cover of flight case 57KG without top cover of flight case 75KG with top cover of flight case 60KG without top cover of flight case Accessories AQUAFOG...

Страница 30: ...A Q U A F O G 2 5 0 0 A Q U A F O G 3 6 0 0 Save this instruction properly All the information is subject to change without prior notice...

Отзывы: