ST325 User Handbook

 

10 

T

e

mperature Disp

aly 

Temperature Display 

1020

 

°C 
°C/hr 
hr.min 

For multi-zone kilns the temperature of 
each zone can be displayed.  Zone 1 is 
displayed by default when the ST325 is 
powered on.   

Ch 1

 

°C 
°C/hr 
hr.min 

To check which zone / channel is currently 
displayed press the 

©

 

or

 

ª

 

keys.  The 

zone temperature will be displayed again 
after 5 seconds or if the 

¨

or 

§

 keys are 

pressed. 

Ch 2

 

°C 
°C/hr 
hr.min 

To change the displayed zone / channel 
press either the 

©

 

or

 

ª

 

keys again.  

Ch 1

 

Ch 2 

will be shown for 2-zone kilns and  

Ch 3

 will be shown for 3-zone kilns. 

1023

 

°C 
°C/hr 
hr.min 

To display the zone temperature either 
wait 5 seconds or press the 

¨

or 

§

 keys. 

This section only applies to multi-zone (2 or 3 zones) kilns.  A single zone 
kiln will always show the temperature of zone 1 only. 

ST325 User Handbook

 

 

 

 

 

       

Page

  

15 

If the ST325 is programmed to heat the kiln at a faster rate than the kiln is 
capable of then the ST325 will turn on full power then wait until the kiln 
temperature has risen to the correct temperature before proceeding to the 
next ramp or soak segment. 
 
Likewise if the ST325 is programmed to cool the kiln at a faster rate than 
the kiln is capable of then the ST325 will apply zero power then wait until 
the kiln has cooled to the correct temperature before proceeding to the 
next ramp or soak segment. 

Kiln too slow 

Heating & Cooling Ramps 

The ST325 is capable of controlled ramps for both heating and cooling.  
The type of ramp required is determined by comparing the required soak 
temperature to the soak temperature in the previous segment and is shown 
on the mimic display. 

STOP key operation 

If the START/STOP key is pressed during a firing then the firing will be 
halted (not paused).  Pressing the START/STOP key again will cause the 
ST325 to restart the firing from the beginning.  The ST325 will look at the 
current kiln temperature and if this is greater than the required soak tem-
perature then the ST325 will automatically 

cool 

from current temperature to 

the soak temperature.  This may not be what is desired so the STOP key 
should only be used to halt the firing in an emergency. 
 
The program can be paused or program data can be changed while the 
controller is firing (see page 14).  This is a better option than using the 
STOP key.  The segment advance feature (see page 16) is however avail-
able to recover quickly from STOP key operation if required. 

Memory 

All programs & necessary data are remembered when the ST325 is turned 
off.  In the event of power failure during firing the ST325 will automatically 
resume firing when power is returned (this feature can be disabled: see 
installation handbook). 

Operating Notes 

Delayed Start 

The delayed start time period is by default set to 

00

.

00

 

when the ST325 is 

turned on. This zeroing feature can be changed to allow a previously en-
tered delayed start time to be remembered: see installation handbook. 

Operating Notes 

Содержание ST325

Страница 1: ...ime hr min Notes Please photocopy me Please photocopy me ST325 User Handbook Page 1 ST325 User Handbook ST325 Temperature Programmer TAFFOR S D Stafford Instruments Ltd Tel 44 0 1785 255588 Fax 44 0 1785 255589 www staffordinstruments co uk email support stafford inst co uk Issue 1 02 Date 21 Feb 2011 See separate handbook for User Instructions Copyright 2011 Stafford Instruments Ltd ...

Страница 2: ...nvestigated and rectified by your installer or kiln service engineer Technical note any error message will cause the alarm relay to open see installation handbook for details Note these error messages are provided to detect kiln faults and so offer some protection to the kiln For increased protection the use of a heat fuse or other independent over temperature trip is recom mended such as the Staf...

Страница 3: ... The kiln temperature exceeds the desired temperature by at least 10 C 50 C installer selectable Err5 C C hr hr min Error 6 Maximum firing time exceeded The length of the current firing has exceeded an installer selectable 10 999 hours limit Err6 C C hr hr min Possible causes are contactor failure or thermocouple connection intermittent or high resistance ST325 User Handbook Page 3 Quick Start Gui...

Страница 4: ...the firing the fan remains off while the kiln temperature is below the fan start temperature The fan starts when the kiln temperature has risen to the fan start temperature and remains on until the kiln tem perature has risen to the fan stop temperature The fan then turns off and stays off until the end of the program The instrument will now reset and the new fan control temperatures will be store...

Страница 5: ...he firing and when the kiln has cooled naturally to the damper open temperature the damper will open Control Relay ST325 User Handbook Page 5 Turning On tC r tC S tC n tC K When turned on the ST325 performs a display test by briefly illuminating all of the display digits and all of the front panel lamps The version number of the embedded software is now displayed If you need technical support you ...

Страница 6: ...utput a fan control output or an event output 00 15 C C hr hr min While displaying a soak time the event relay can be switched on or off by hold ing in the fn function key then pressing the event key The event relay will be closed when the event lamp is on Control Relay Event Output Card Reader This controller has a card slot for a micro SD mem ory card the same type of card as used on many mobile...

Страница 7: ...amp it was pre viously executing For power failure during soaking the ST325 ramps back up to soak tem perature at the correct ramp rate then applies the remaining soak period Power failure recovery can be disabled if required see installation hand book the ST325 will then lock up with FAIL displayed and kiln off in the event of power failure ST325 User Handbook Page 7 When not firing no lamps lit ...

Страница 8: ...d This can be confirmed by stepping through the completed program with the key Q A During programming End is displayed when I want to enter another segment why is this Available ramp rate displays are End 1 999 FULL If End is shown but another segment is required then push the key to obtain the required ramp rate in the range 1 C hr to 999 C hr If full power is required then push the key until FUL...

Страница 9: ...amics Programs Note It has been found that a kiln controller will give greater heat work as the temperature increases Therefore to achieve a stoneware firing of cone 8 9 we suggest setting the final soak temperature to 1235 C A slight adjustment can then be made after the first firing It should be remembered that kiln controllers are indicators of temperature and the effects of faster or slower fi...

Страница 10: ...eating Cooling Ramps The ST325 is capable of controlled ramps for both heating and cooling The type of ramp required is determined by comparing the required soak temperature to the soak temperature in the previous segment and is shown on the mimic display STOP key operation If the START STOP key is pressed during a firing then the firing will be halted not paused Pressing the START STOP key again ...

Страница 11: ...onds If the kiln has a contactor then a loud click will be heard both when the decimal point lights up and when it goes out If full heating power is required then the decimal point will remain lit If full cooling is required then the decimal point will remain off Firing Hint it is good practice to check that the program is correct by pressing the key checking the program number program contents be...

Страница 12: ... Kilncare Ltd www kilncare co uk and The Creative Glass Guild www creativeglassguild co uk Sample Glass Programs ST325 User Handbook Page 13 2 mp te hr Seg 2 Soak Temp C Seg 2 Soak Time hr mn Seg 3 Ramp Rate C hr Seg 3 Soak Temp C Seg 3 Soak Time hr mn Seg 4 Ramp Rate C hr Seg 4 Soak Temp C Seg 4 Soak Time hr mn Seg 5 Ramp Rate C hr L 840 00 20 FULL 538 00 45 182 427 00 15 End L 824 00 20 FULL 538...

Отзывы: