     ST312A 

User 

Handbook 

18 

Other Features 

Energy Used Display 

Pressing the 

§

 button at any time shows the amount of electrical energy used 

in kW hours.  If pressed during a firing it shows the energy used so far.  After 
a firing it shows the total energy used for that firing.  This information is 
stored while power is off and is only reset to zero when a new firing is 
started. 
 
If the value displayed is always 

0

.

0

 then the kiln power rating has not been 

configured into the ST312A - see installation handbook. 

Keyboard Lock Facility 

1

.

200

 

°C 
°C/hr 
hr.min 

The keys on the ST312A can be locked so that pressing them has no effect.  
This is an anti-tamper feature used to ensure that the operation of the 
ST312A or the program data cannot be altered by un-authorised people.  
The ST312A can be locked when it is idle (not firing) or while it is firing.  It 
cannot be locked while it is being programmed. 

If the left-hand decimal point in the dis-
play is lit then the ST312A is locked.  
Press and hold in both the 

©

 & 

ª

 keys  

for 5 seconds to unlock the ST312A. 

1200

 

°C 
°C/hr 
hr.min 

If the left-hand decimal point in the display 
is not lit then the ST312A is not locked.  
Press and hold in both the 

©

 & 

ª

 keys  for 

5 seconds to lock the ST312A. 

Power Failure Recovery 

If power fails during firing then the ST312A recovers as follows:- 
For power failure during start delay the ST312A commences firing immedi-
ately when power returns.  For power failure during ramp 1 or ramp 2 the 
ST312A goes back into the ramp it was previously executing.  For power 
failure during soaking the ST312A ramps back up to soak temperature at 
ramp rate 2 then applies the remaining soak period.  This recovery scheme 
can be disabled if required (see installation handbook) - the ST312A will 
then lock up with 

FAIL

 displayed and kiln off in the event of power failure. 

Other

 Featur

es 

ST312A User Handbook 

 

 

 

 

       Page   3 

Quick S

tart Guide 

Quick Start Guide 

Switch on & wait for kiln temperature display 

To run a firing program set up previously press the 
START/STOP key

 

To stop the firing at any time press the START/
STOP key again

 

To review firing data press the 

¨

 key to enter the 

programming menu

 

To change firing data press the 

©

 & 

ª

 keys to 

change the displayed value

 

Use the 

¨

 key again as necessary to index to the 

next firing value to be reviewed or changed

 

To exit the programming menu either wait 10 sec-
onds or press the START/STOP key to start firing 

If the keyboard is locked then press the 

©

 & 

ª

 keys 

together & hold down for 5 seconds to unlock

 

Содержание ST312A

Страница 1: ...df ST312A User Handbook Page 1 ST312A User Handbook ST312A Temperature Programmer TAFFOR S D Stafford Instruments Ltd Tel 44 0 1785 255588 Fax 44 0 1785 255589 www staffordinstruments co uk email support stafford inst co uk Issue 2 00 Date 01 June 2009 See separate handbook for User Instructions Copyright 2009 Stafford Instruments Ltd ...

Страница 2: ...0 30 Earthenware Mid Temperature Glaze 90 C hr 600 C 00 30 Earthenware High Temperature Glaze 90 C hr 600 C 00 30 Stoneware Glaze 90 C hr 600 C 00 30 On Glaze Enamel 90 C hr 600 C 00 30 Heavy Sculpture 50 C hr 300 C 00 30 Lustre 90 C hr 600 C 00 00 Ramp 2 FULL FULL FULL FULL FULL FULL FULL FULL 70 C hr FULL Soak temp 960 C 1000 C 1160 C 960 C 1040 C 1140 C 1250 C 780 C 1000 C 750 C Sample Programs...

Страница 3: ...t locked Press and hold in both the ª keys for 5 seconds to lock the ST312A Power Failure Recovery If power fails during firing then the ST312A recovers as follows For power failure during start delay the ST312A commences firing immedi ately when power returns For power failure during ramp 1 or ramp 2 the ST312A goes back into the ramp it was previously executing For power failure during soaking t...

Страница 4: ... to terminate the firing with all the keys locked An alarm buzzer sounds once per second SWITCH KILN OFF To reset the ST312A turn off the power to the instrument and have the fault investigated by your installer or kiln service engineer to rectify the fault Technical note any error message will cause the auxiliary alarm relay if fitted to open see installation handbook for details Note these error...

Страница 5: ...hours limit Err6 C C hr hr min Possible causes are contactor failure or thermocouple connection intermittent or high resistance ST312A User Handbook Page 5 Turning On F1 04 tC r tC S tC n tC K 8 8 8 8 When turned on the ST312A performs a display test by briefly illuminating all of the display digits and all of the front panel lamps The version number of the software embedded within the ST312A is n...

Страница 6: ...ogram Pause Facility While firing press and hold down the ª key for about 4 seconds The ST312A will pause the executing program To un pause the program press and hold down the ª key again for about 4 seconds The effects of pausing are as follows If paused during a ramp the kiln temperature will be held soaked indefi nitely at the current kiln temperature The ramp will continue when un pause is sel...

Страница 7: ...re If currently soaking then the ST312A will end the firing Changes made to the operation of the ST312A in this way are temporary and are not stored Adjusting While Firing ST312A User Handbook Page 7 When the ST312A is not firing there are no lamps lit on the mimic panel the run lamp is off and the display shows the kiln temperature with the C indicator lit Altering the program 20 C C hr hr min If...

Страница 8: ...se through the programming steps to correct errors or to exit programming mode Note available ramp rate displays are End 1 999 FULL If End is shown but another segment is required then push the key to obtain the required ramp rate in the range 1 C hr to 999 C hr If full power is required then push the key until FULL is diplayed ST312A User Handbook Page 13 Cooling Upon completion of firing the ST3...

Страница 9: ...feature can be disabled see installation handbook Firing Delayed Start The delayed start time period is set to 00 00 when the ST312A is turned on ST312A User Handbook Page 9 Firing To start a firing press the START STOP key The RUN lamp will light To stop the firing prematurely press the START STOP key again 20 C C hr hr min If the left hand decimal point is on then the keyboard is locked the ST31...

Страница 10: ...Page ST312A User Handbook 10 Program Record Sheet Ramp 1 C hr t1 C Ramp 2 C hr Soak Temp C Soak Time hr min Please photocopy me ST312A User Handbook Page 11 Program Description Please photocopy me ...

Отзывы: