Rev1/Nov ‘98
5
Figure 3. Wall controller showing changes to fan operation.
Run Time Button
This button allows you to preset the time at which your cooler turns on or off.
If the unit is operating and you press the “RUN TIME” button all the light indicators will go
blank. If you press the “STEP” button the lowermost light will be illuminated. This indicates that the
unit will turn off in one (1) hour (the off time). Each subsequent press of the “STEP” button delays the
unit turning off by one more hour. This will be indicated by the light moving clockwise around the dial
as shown in Figure 4. If having reached the ten (10) hour mark and the “STEP” button is pressed
again the off time will return to zero (0). If the “RUN TIME” button is pressed again the display will
return to the state it was in before activating the “RUN TIME” button for the first time, i.e. it will return to
that shown in Figure 1 or Figure 2, depending on which mode the unit is operating. The light beside
the “RUN TIME” button will now flash, indicating the number of hours left before the unit turns off. At ½
an hour to the turn on or turn off time the small red light beside the “RUN TIME” button will flash rapidly,
until the unit either turns on or off.
If the unit is not operating and the “RUN TIME” button is pressed this will set the time at which
the unit will turn on. If you press the “STEP” button the lowermost light will be illuminated. This
indicates that the unit will turn on in one (1) hour, the “on time”. Each subsequent press of the “STEP”
button delays the unit turning on by one more hour. This will be indicated by the light moving clockwise
around the dial as shown in Figure 4. Unlike in Figure 4 the lights beside either of the “ON/OFF COOL”
or “FAN ONLY” button will not be illuminated, as the unit is not currently operating. Again, if having
reached the ten (10) hour mark and the “STEP” button is pressed again the on time will return to zero
(0). Pressing the “RUN TIME” button a second time will clear the main display of lights. The light
beside the “RUN TIME” button will now flash, indicating the number of hours left before the unit turns
on. Having counted down to the on time the unit will automatically turn on and select the lowest
temperature setting which also automatically sets the fan speed.