background image

Stabila LD420

Safety Instructions

19

EN

FCC statement (applicable in U.S.)

This equipment has been tested and found 

to comply with the limits for a Class B 

digital device, pursuant to part 15 of the 

FCC Rules. These limits are designed to 

provide reasonable protection against 

harmful interference in a residential instal-

lation.This equipment generates, uses and 

can radiate radio frequency energy and, if 

not installed and used in accordance with 

the instructions, may cause harmful inter-

ference to radio communications.

However, there is no guarantee that inter-

ference will not occur in a particular instal-

lation. If this equipment does cause 

harmful interference to radio or television 

reception, which can be determined by 

turning the equipment off and on, the user 

is encouraged to try to correct the interfer-

ence by one or more of the following 

measures:

Reorient or relocate the receiving 

antenna.

Increase the separation between the 

equipment and receiver.

Connect the equipment into an outlet on 

a circuit different from that to which the 

receiver is connected.

Consult the dealer or an experienced 

radio/TV technician for help.

Laser classification

The device produces visible laser beams, 

which are emitted from the instrument:

It is a Class 2 laser product in accordance 

with:

IEC60825-1 : 2007 „Radiation safety of 

laser products“

Laser Class 2 products:

Do not stare into the laser beam or direct it 

towards other people unnecessarily. Eye 

protection is normally afforded by aversion 

responses including the blink reflex.

WARNING

Looking directly into the beam with optical 

aids (e.g. binoculars, telescopes) can be 

hazardous.

CAUTION

Looking into the laser beam may be 

hazardous to the eyes.

Labelling

Subject to change (drawings, descriptions 

and technical data) without prior notice.

Laser Radiation 

Do not stare into the beam 

Laser class 2 

acc. IEC 60825-1:2007 

Maximum radiant power: <1mW 

Emitted wavelength: 620-690nm 

Beam divergence: 0.16 x 0.6 mrad 

Impulse duration: 0.2 x 10

-9

s - 0.8 x 10

-9

s

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание LD420

Страница 1: ...Divide 6 Area 7 Volume 8 Special Functions 9 Pythagoras 1 10 Pythagoras 2 3 point 10 Pythagoras 3 partial height 11 Stake out 12 Trapezoid 13 Memory 14 Settings 15 Technical Data 16 Message Codes 17 C...

Страница 2: ...d will result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor injury and or appreci able material financial...

Страница 3: ...Wall area Addition Subtraction Timer Memory Pythagoras Battery Min Max Measuring Illumination Main line Tilt angle Battery Insert batteries i To ensure a reli able use do not use zinc carbon batterie...

Страница 4: ...ration mode If the message InFo appears with a number observe the in structions in section Message Codes Example Adjusting measuring reference tripod Next distance is measured from the front of the de...

Страница 5: ...ons 5 EN Multifunctional endpiece i The orientation of the endpiece is automatically detected and the zero point is accordingly ad justed www GlobalTestSupply com Find Quality Products Online at sales...

Страница 6: ...sible 3rd row shows a line min max 2 Stops permanent minimum maximum measuring With pressing the equal button the max or min value can be moved in the main line for calculation afterwards 3 Add Subtra...

Страница 7: ...distances above Partial Measurements Press or after starting the first measurement Measure and add or subtract distanc es Finish with MENU Meas ure 2nd length 7 230 m Circumference 6 2 559 m Diagonal...

Страница 8: ...184 m 1 725 m 1 890 m 7 i The result is shown in the main line and the measured distances above 7 230 m 8 Circumfer ence 8 560m2 9 Wall areas 2x 3 260m2 10 Ceiling floor area 3x i With the MENU key a...

Страница 9: ...er functions are located in a menu structure All special functions can directly started by pressing the On Measure key after selection Following special functions are available Pythagoras Pythagoras 2...

Страница 10: ...i mum measure ment Pythagoras 2 3 point 1 2 Aim laser at up per point 3 4 Aim laser at rec tangular point 5 6 Aim laser at lower point 2 52i m 4 004 m 3 936 m 4 322 m 7 i The result is shown in the ma...

Страница 11: ...6 m 4 032 m 4 293 m 4 419 m 7 i The result is shown in the main line and the measured distanc es above Pressing the measuring key for 2 sec in the function activates automatically Minimum or Maximum m...

Страница 12: ...prove value a i 000 m 4 Adjust value b 5 Approve value b and start measurement 6 Move device slowly along the stake out line The distance to the next stake out point is dis played 0 238 m 1 012m 1 000...

Страница 13: ...laser at rec tangular point 4 i06 m 4 651 m 2 554 m i 437 m 7 i The result is shown in the main line and the measured distanc es above With the MENU key additional results can be selected 5i 53 4 i04...

Страница 14: ...e 1 2 sec Select position in memory 2 Tipp Store val ues like PI or the price per square meter for calcu lations 3 Set or change value 1 Press and to gether to start change mode 00 000 m 2 Selected di...

Страница 15: ...n1 32 0in1 16 0in1 8 4 Laser Continuous On Off 5 Display Backlight Time 0 99sec 99sec permanent 6 Beep On Off 7 Offset On Off 8 Offset value 9 Reset No Yes In order to change the setting move to the d...

Страница 16: ...le condition 60 m 197 ft Smallest unit displayed 0 1 mm 1 32 in laser point at distances 6 30 60 mm 10 50 100 m General Laser class 2 Laser type 635 nm 1 mW Protection class IP65 dust tight and jet wa...

Страница 17: ...Drive South Elgin IL 60177 1 800 869 7460 The company above is responsible for supplying the product including the User Manual in a completely safe condition The company above is not responsible for...

Страница 18: ...ring and after important measurements CAUTION Never attempt to repair the product your self In case of damage contact a local dealer WARNING Changes or modifications not expressly approved could void...

Страница 19: ...equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Laser...

Отзывы: