background image

en

Checking the angular accuracy to 90° :

The check is carried out using the target plate ZP !

1. Select a measuring section with a minimum length of 10 m  / 32‘10“.  

     Mark point A on the floor at one end of the section.

2. Align the intersection of the laser lines over point A. 

3. Mark point B on the floor roughly in the middle of the section and

     point C at the end.

4. Move theFLS 90 to point B and realign laser line 1  ( L1) on point „C“.

5. Mark position „D“ of the right-angle laser line 2 (L2) on the floor.

Note:

For a precise check, the distances from A to B, B to C and B to D should be 

approximately the same.

6. Rotate the FLS-90 through 90° so that laser line 1 (L1) is aligned with point „D“.

7. Mark the position E of the right-angled laser line 2 (L2) at the shortest

    distance to point A on the floor.

8. Measure the distance between points „A“ and „E“.

Section between 

points A and C

S

Each of the 90° angles are accurately

calibrated if the distance between

points „A“ and „E“ is as follows:

10 m

≤   3,0 mm

20 m

≤   6,0 mm

32'10"

≤   1/8“

  65'  8"          

≤   1/4“

Replacing the batteries

Slide the battery cover (4) in the direction of the arrow and insert new 

batteries in accordance with the symbols in the battery compartment.

Suitable batteries can also be used.

Technical data

Laser type:     

 

Red diode laser, pulsed line-laser,

   wavelength  635 nm
Output:  

 

< 1 mW, Laser Class 2   to IEC 60825-1:2007

                                                                    This product compl. with the appl. requ. 

                                                               of 21CFR, parts 1040.10 and 1040.11.
Line straightness : 

                 ± 0,3 mm/m       3/16“  over 50 ft

Accuracy 90° angle  :              

± 0,3 mm/m       3/16“  over 50 ft

Batteries:   

               

3 x 1,5 V mignoncells Alkaline, Size AA, LR6

Operating life: 

               

Approx. 20 hours (Alkaline)

Operating temperature range : 

-10 °C  to  +50 °C       /     14°F to +122°F

Storage temperature range:              -25 °C  to  +70 °C       /    -13°F to +158°F
Subject to technical modifications.

*  When operated within specified temperature range