background image

Do not store the laser when wet. Dry 

the laser and case before putting 

the laser away. 

Do not submerge the laser.

Do not unscrew !

Operating status display and error messages 

via the LEDs

Illuminated 

green

 LED

-> laser in operation

Illuminated 

green

 LED 

 

+ laser beam

 flashing

-> The laser levels itself automatically

Flashing

 

green

 LED 

 

+ laser beam

 flashing

-> The unit is inclined too much 

    + is outside the self-levelling range 

    + the laser cannot level itself automatically

Illuminated

 red 

LED

-> laser in operation

-> battery voltage very low

-> battery replacement required imminently

Illuminated

 red 

LED

 

+ laser beam

 flashing

-> The laser levels itself automatically

-> Battery voltage very low 

-> Battery replacement required imminently

Flashing

 

red

 LED 

 

+ laser beam

 flashing

-> Battery voltage very low

-> The unit is inclined too much 

    + is outside the self-levelling range 

    + the laser cannot level itself automatically

-> The temperature in the unit is over 50°C / 122°F

-> The laser diodes have been switched off to protect 

   against overheating

-> Place the unit in the shade to be able to continue  

    working.

-> The laser is not working

Only LA-180L: 

The LEDS flash red

                     + green

 + laser cannot be seen

The LEDS

 flash red + 

green alternately 

The LEDS 

flash 

3 x during 

a period of 3 seconds

The appliance is in registration mode

The registration was successful

Содержание LA 180L

Страница 1: ...LA 90L LA 180L Operating instructions en ...

Страница 2: ...A 3a 3b 4 5 6 7 8 LA 180L ...

Страница 3: ...1d 1c 1a 1b 2b 2a B LA 180 L LA 90 L C A1 ...

Страница 4: ...E1 E2 D1 90 2 8m D2 1 1 2 E3 1 2 D D X Y F 5 11 ft 3 1 3 ft Y Y 1m ...

Страница 5: ...1 A G4 2 B 1 A 2 B 1 A 2 B 2 3 S 5 m 16 ft 3 1 3 G1 D3 2 8m G5 G3 G2 11 ft ...

Страница 6: ...y time Telephone number 0049 63 46 3 09 0 Main components 1a 1b 1c 1d 2 2a 2b 3a 5 6 7 8 9 On off button Button automatic levelling on off manual mode Button horizontal line on off Button vertical lines on off LEDs for displaying LED green Operating mode ON or READY OK LED red battery voltage and overheat Exit aperture for the horizontal and vertical laser lines Adjusting screw precision adjustmen...

Страница 7: ...yes are normally protected from accidental short term exposure to the laser beam by the lid closing reflex and or the reflex reaction to turn one s head If a laser beam should encounter your eye you should consciously close your eyes and immediately move your head out of the beam Do not look directly into the direct or reflected beam The laser goggles enclosed with these units are not safety goggl...

Страница 8: ...uch is outside the self levelling range the laser cannot level itself automatically Button 1d different vertical laser lines can be switched on off in succession The plumb line point is also switched on off at the same time All the vertical laser lines can only be switched off if the horizontal laser line is switched on If button 1d is pressed again the vertical laser lines are switched on again i...

Страница 9: ...n 1d 4 Place the laser so that its down beam is aligned over a reference mark on the floor 5 Mark the position of the laser cross on the ceiling 6 Rotate the laser through 180 and realign the laser beam on the reference mark on the floor 7 Mark the position of the laser cross on the ceiling 8 Measure the differences in the x and y directions between the two marks on the ceiling The difference is t...

Страница 10: ...A B C D E A E I2 L 10m H3 H2 A B C D L 10m H1 A B C I3 I1 16 5 32 10 16 5 16 5 16 5 16 5 16 5 32 10 ...

Страница 11: ...the angular accuracy of the vertical lines checking the 90 angle of the vertical lines Note In order to guarantee accuracy the distance of A to B B to C and B to D should be equal 7 Rotate the LA 90L LA 180L through 90 so that laser line 1 is aligned with point D 8 Mark position E of the right angle laser line 2 as close as possible to point A on the floor 9 Measure the distance between points A a...

Страница 12: ...first wall step 3 point 1 2 Horizontal checking inclination of the laser line Check the laser line for inclination and perfectly straight projection 1 Mark three points 1 2 and 3 on the floor at a distance of 5 m 16 5 from each other the points must be in a perfectly straight line 2 Position the laser at distance S 5 m 16 5 from the line and exactly in front of the middle point you marked position...

Страница 13: ...g period Only LA 180L Registering the REC 410 Line RF receiver with the laser transmitter 1 Switch off the laser transmitter button 1a 2 Press and hold down buttons 1c and 1d 3 Switch the unit on button 1a 4 The laser transmitter is in registration mode The LEDs red and green flash alternately 5 Press the button automatic precision alignment d on the REC 410 Line RF receiver 6 The red and green LE...

Страница 14: ...ed imminently Illuminated red LED laser beam flashing The laser levels itself automatically Battery voltage very low Battery replacement required imminently Flashing red LED laser beam flashing Battery voltage very low The unit is inclined too much is outside the self levelling range the laser cannot level itself automatically The temperature in the unit is over 50 C 122 F The laser diodes have be...

Страница 15: ...ty Also no claims under guarantee are accepted for natural wear and tear or any small faults that do not significantly affect the unit s operation Any guarantee claims must be made via the dealer on the duly completed guarantee form see last page to be returned with the unit Technical data Laser type line Laser type plumb line point Output Self levelling range Levelling accuracy Middle of the lase...

Отзывы: