STA-RITE MAX-E-THERM 77707-1341 Скачать руководство пользователя страница 1

MAX-E-THERM

POOL HEATER

FUEL GAS CONVERSION KIT

NATURAL GAS TO PROPANE (LPG)

S   E   R   V   I   C   E

M   A N   U   A L

INSTALLATION INSTRUCTIONS

Kit No. 77707-1341 converts Models SR/SRC400NA and SR400HD to Propane (LPG)

Kit No. 77707-1351 converts Models SR/SRC333NA to Propane (LPG)
Kit No. 77707-1361 converts Models SR/SRC200NA to Propane (LPG)

Sta-Rite Pool/Spa Group

293 Wright Street, Delavan, WI 53115

International:

262-728-5551, FAX: 262-728-7550

www.starite.com

Union City, TN • Delavan, WI • Mississauga, ON

© 2005, Sta-Rite Industries    

S630 

(Rev. 11/30/05)

Failure to follow instructions could result in fire or explosion with

serious injury or property damage. This conversion kit shall be installed by
a qualified service agency in accordance with the manufacturer’s instruc-
tions and all applicable codes and requirements of the authority having
jurisdiction. The information in these instructions must be followed to mini-
mize the risk of fire or explosion or to prevent property damage, personal
injury, or death. The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specified in the manu-
facturer’s instructions supplied with the kit.

IN CANADA: “THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS
OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIRE-
MENTS OF THE 

CAN-B149.1 AND CAN-B149.2 INSTALLATION CODE.”

This kit is for the purpose of converting a Sta-Rite Max-E-Therm™ heater from natural gas to Propane
(LPG). It is not designed to alter the input to the appliance and must not be used to attempt to alter the
input from the original nameplate rating.

The term “qualified agency” means any individual, firm, corporation or company which either in person or through a
representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connec-
tion, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions
required, and has complied with all the requirements of the authority having jurisdiction. A Sta-Rite distributor with
service personnel trained to install or repair gas heaters is a qualified agency.

NOTICE: See “Blower Identification Notice,” Page 6

Содержание MAX-E-THERM 77707-1341

Страница 1: ...llation of this kit The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manu facturer s instructions supplied with the kit IN CANADA THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIRE MENTS OF THE CAN B149 1 AND CAN B149 2 I...

Страница 2: ...erential pressure gauge or slope gauge inclined manometer capable of reading to a resolution of 0 05 W C the Low Pressure Gauge 1 Flue gas analyzer reading either CO2 or O2 Do not attempt the conversion without all the listed tools and instruments GAS CONNECTIONS The heater requires a gas supply of not less than 4 10 2cm wc and not more than 14 35 6cm wc Gas supply pressures outside of this range ...

Страница 3: ...opane orifice included in your kit see Table 2 Table 2 Replacement Propane Orifice Size Code Model Part No ID Stamp Size SR SRC400 42001 0341 D 409 SR SRC333 42001 0351 E 340 SR SRC200 42001 0361 F 244 8 Insert the Propane orifice squarely in the gas line union next to the combination gas valve see Figure 4 9 Swing the gas loop and union half back into place and tighten both unions securely 10 Tig...

Страница 4: ...ÈtreutilisesilatempÈ raturede líeau estinfÈrieure 10 C 50 F CeestcertifiÈpour ÍtreinstallÈsurun solcombustible POURL INSTA LLATION L EXT RIEUR DÈgagementminimum avec toutes matiËrescombustibles dessus dÈ gage 152m mde chaque cÙ te 152m m l arriËre N installezpasce chauffe piscine sous un surplombse trouvant moins de 914m mdu dessus du chauffe piscine La partiese trouvantsous le surplombdoitÍtreouv...

Страница 5: ...0 200 000BTU Hr Model SR SRC333 333 000BTU Hr Model SR SRC400 399 990BTU Hr Sequence Of Operation For detailed information please refer to Sta Rite Pool Spa Heater Training and Service Manual publication no S5066 An electronic temperature sensing thermistor in the mani fold adapter inlet controls the heater operation When the inlet water temperature drops below the temperature set on the operating...

Страница 6: ...lower looks like the one on the left you MUST NOT replace the orifices with the ones in this kit Gas and Air Orifices are not interchangeable between the two blower types This kit must match your heater s fuel type when service is complete Propane or Natural Gas its BTU rating 200K 333K or 400K and its blower type If any of these items do not match DO NOT INSTALL THE KIT Call 1 800 752 0183 to ord...

Страница 7: ...pas adéquate ni terminée tant que le fonctionnement de l appareil converti n a pas été vérifié comme le spécifient les instructions du fabricant livrées avec ce nécessaire AU CANADA LA CONVERSION DOIT ÊTRE EFFECTUÉE CONFORMÉMENT AUX SPÉCIFICATIONS DES AUTORITÉS PROVINCIALES AYANT COMPÉTENCE ET CONFORMÉMENT AUX SPÉCIFICATIONS DES CODES D INSTALLATION CAN B149 1 ET CAN B149 2 Ce nécessaire n est pré...

Страница 8: ...el ou un manomètre à tube incliné pou vant relever une résolution ayant jusqu à 0 05 po à la colonne d eau contrôleur basse pression 1 Analyseur de gaz brûlés pouvant relever les CO2 et les O2 Ne pas essayer de procéder à la conversion si l on ne possède pas les instruments et les outils énumérés BRANCHEMENTS DU GAZ L arrivée du gaz au chauffe piscine spa doit être d au moins 4 pouces 10 2cm à la ...

Страница 9: ...2001 0341 D 0 409 SR SRC333 42001 0351 E 0 340 SR SRC200 42001 0361 F 0 244 8 Introduire bien d équerre l ajutage de propane dans le raccord union de la conduite de gaz le plus proche de la soupape à gaz mixte voir la Figure 4 9 Ramener la conduite de gaz et l autre moitié du raccord union en position et serrer fermement les deux moitiés du raccord union 10 Serrer le collier retenant la conduite d...

Страница 10: ...0183 COMPOSEZ LE 1 800 752 0183 OR Reg No 2 1 81 37 1 R THISPOOLHEATERWAS ANSIZ21 56 2001 CSA4 7 2001 CERTIFIEDFORCOMPLIANCEWITH FO ROUTD OORINSTA LLATION USA CANADA Minimum clearances fromcombustiblematerial top unobstructed 6 fromsides 6 from back Donotinstallthisapplianceunderan overhand less than 3feet 914mm frothetop oftheappliance Th earea undertheoverhang mustbe open on 3sides Recom mendedc...

Страница 11: ...e chaleur du gaz requise BTU h Modèle SR SRC200 200 000 BTU h Modèle SR SRC333 333 000 BTU h Modèle SR SRC400 399 990 BTU h Ordre de fonctionnement Pour des renseignements plus détaillés se reporter au Manuel de réparation et de formation du chauffe piscine spa Sta Rite n de publication S5066 Une thermistance de détection de la température logée côté arrivée de l adaptateur de la tubulure contrôle...

Страница 12: ... ressemble à celle de gauche son injecteur NE DOIT PAS être remplacé par celui livré avec la trousse Les injecteurs d air et de gaz ne sont pas interchangeables entre les deux types de soufflantes Cette trousse doit correspondre au type de combustible du chauffe piscine propane ou gaz naturel aux Btu 200 K 333 K ou 400 K et son type de soufflante Si l un ou l autre de ces éléments ne correspond pa...

Отзывы: