STA-RITE DYNA-PRO MPE6C-204L Скачать руководство пользователя страница 4

4

1. Do not connect system to a high pressure or city water

system.

2. Use equipment only in a pool or spa installation.
3. Trapped air in system can cause explosion. BE SURE all

air is out of system before operating or testing equipment.

Before pressure testing, make the following safety
checks:

• Check all clamps, bolts, lids, and system accessories

before testing.

• Release all air in system before testing.

Water pressure for test must be less than 25 PSI 

(7.5 

kg/cm

2

).

• Water Temperature for test must be less than 100

o

F.

(38

o

C).

• Limit test to 24 hours. After test, visually check system

to be sure it is ready for operation. Remove trap lid and
retighten hand tight only, see Figure 1.

NOTICE:

These parameters apply to Sta-Rite equipment

only. For non-Sta-Rite equipment, consult manufacturer.

NOTICE:

Do not start the pump until the strainer basket

cover is on and the tab, or rib, on the discharge port
aligns between the arrows. 

INSTALLATION

Only qualified, licensed personnel should install pump
and wiring.

Pump mount must:

Be located away from corrosive or flammable liquids. 
Have enough ventilation to maintain air temperature at less
than the maximum ambient temperature rating (Max. Amb.)
listed on the motor model plate. If this pump is installed in
an enclosure/pump house, the enclosure must have ade-
quate ventilation and air circulation to keep the tempera-
ture in the enclosure at or below the motor’s rated ambient
temperature whenever the pump is running.
Be solid - Level - Rigid - Vibration free. (To reduce vibra-
tion and pipe stress, bolt pump to mount.)

IMPORTANT SAFETY 
INSTRUCTIONS

Always follow basic safety precautions with this
equipment, including the following.

To reduce the risk of injury, do not per-

mit children to use this product unless they are closely
supervised at all times.

This pump is for use with permanently

installed pools and may also be used with hot tubs and
spas if so marked. Do not use with storable pools. A
permanently installed pool is constructed in or on the
ground or in a building such that it cannot be readily
disassembled for storage. A storable pool is con-
structed so that it may be readily disassembled for stor-
age and reassembled to its original integrity.

SAVE THESE 
INSTRUCTIONS

Strainer Basket

Cover

Discharge Port

to Filter or Pool

Bonding Lug

Suction

Port

from

Pool or

Vacuum

Filters

Pump may be bolted to level

foundation or mounting bracket.

NOTICE: 

Port threads are: Internal - 2" NPT for direct connec-

tion to pipe. External - 3-1/4" Buttress. Fits Sta-Rite U11-200P
Union Collar for quick disconnect pipe connection.

See Page 13 for Union Kits.

Figure 2

RO

TAT

E L

ID-

RIN

G S

O R

IB O

N PU

MP 

RO

TAT

E L

ID-

RIN

G S

O R

IB O

N PU

MP 

DIS

CH

AR

GE

 AL

IGN

S B

ETW

EEN

 ARR

OWS 

    

    

DIS

CH

AR

GE

 AL

IGN

S B

ETW

EEN 

ARRO

WS 

Ta

b

Discharge 
Port

Arro

w

s

Figure 1 – Strainer basket cover alignment.

Содержание DYNA-PRO MPE6C-204L

Страница 1: ...MPEA and MPE See Page 3 for Model Numbers Pentair Water Pool and Spa Inc Sanford N C Moorpark CA USA Ontario Canada Herentals Belgium S771 Rev B 2 8 08 This manual should be furnished to the end user...

Страница 2: ...d Dyna Pro are trademarks and or registered trademarks of Pentair Water Pool and Spa Inc and or its affiliated companies in the United States and or other counties Teflon is a registered trademark of...

Страница 3: ...njury or major property damage if ignored warns about hazards that can cause death serious personal injury or major property damage if ignored warns about hazards that will or can cause minor personal...

Страница 4: ...nd air circulation to keep the tempera ture in the enclosure at or below the motor s rated ambient temperature whenever the pump is running Be solid Level Rigid Vibration free To reduce vibra tion and...

Страница 5: ...the pump To avoid a strain left by a gap at the last connection start all piping at the pump and run pipe away from the pump To avoid airlocking slope suction pipe slightly upward toward the pump NOTI...

Страница 6: ...Mechanical Officials IAPMO standards Use only non entrapping suction fitting or double suction ELECTRICAL Ground motor before connecting to electrical power supply Failure to ground motor can cause se...

Страница 7: ...f power outage check GFCI for tripping which will prevent normal pump operation Reset if necessary NOTICE If you do not use conduit when wiring motor be sure to seal wire opening on end of motor to pr...

Страница 8: ...25 15 16 0 8 0 115 230 60 1 12 14 3 2 8 14 8 4 2 6 14 14 2 2 15 10 4 230 60 1 14 2 14 2 12 3 2 1 2 15 11 2 230 60 1 14 2 14 2 12 3 MPRA SERIES TWO SPEED 1 1 2 1 4 15 9 2 2 5 230 60 1 14 2 14 2 12 3 MP...

Страница 9: ...e Figure 1 Page 4 Pump should prime now Priming time will depend on vertical length of suction lift and horizontal length of suc tion piping If pump does not prime make sure that all valves are open s...

Страница 10: ...ution to not break attached piping 6 Be sure motor is kept dry and covered Startup For Winterized Equipment 1 Remove any temporary weather protection placed around system for shutdown 2 Follow filter...

Страница 11: ...d free of dirt grease dust etc Wet outer edge with small amount of liquid detergent press ceramic seat into seal plate cavity firmly and squarely with finger pressure Figure 7 2 If ceramic seat will n...

Страница 12: ...ogged follow steps 1 through 7 under Removing Old Seal Page 11 check impeller for clogging follow steps 7 through 11 under Installing New Seal Page 11 for reassembly 9 Impeller and diffuser may be wor...

Страница 13: ...LL MPE6C 204L 1 2 AE100CHL MPE6D 205L 3 4 AE100DHL MPE6E 206L 1 AE100EHL 230 60 1 MPRA6G 207L 2 A100GLL MPEA6G 207L 2 AE100GLL MPEAA6G 208L 2 1 2 AE100G5LL MPE6F 207L 1 1 2 AE100FHL MPE6G 208L 2 AE100...

Страница 14: ...440 35505 1440 35505 1440 35505 1440 35505 1440 14 Trap Basket 1 C8 58P C8 58P C8 58P C8 58P C8 58P 15A Drain Plug 2 U178 920P U178 920P U178 920P U178 920P U178 920P 15B Mounting Screw 5 16 14x5 8 2...

Страница 15: ...15...

Страница 16: ...P N S771 Rev B 2 8 08...

Отзывы: