STA-RITE DURA-JET JSACL Скачать руководство пользователя страница 7

7

OPERATION

Priming Pump:

NEVER run pump dry! Running pump dry may damage seals, causing

leakage and flooding! Fill pump with water before starting motor.

Do not add chemicals to spa system directly in front of pump suction.

Adding undiluted chemicals may damage pump and voids warranty.

Open gate valves before starting system.

Pump will prime itself when used in flooded suction system.

Be sure to release all air from filter and piping system; see spa/filter owner’s
manual.

On two speed models, low speed is used for filtration and heating; high speed
provides therapy jet action.

Do not block pump suction! To do so with body may cause severe or

fatal injury. Small children using spa must ALWAYS have close adult 

supervision!

NOTICE: 

Do not block jets! To do so may flood area causing damage to

equipment and water damage to surrounding area.

Water:

Keep water level at least two inches above botom of skimmer opening when
system is not in use. Failure to do so can allow air to enter system, causing
pump to lose its prime.

Keep water temperature at 104°F (40°C) or below.

Age or health conditions may require a lower temperature; consult a physi-
cian for more information.

If in doubt, start at a lower temperature and gradually increase it according to
your experience.

Keep an accurate thermometer in bath; check it before getting in.

Do not use or allow the use of the tub by anyone using alcohol or

drugs. The effects of hot water, alcohol and/or drugs can cause dizzi-

ness and falling, loss of consciousness, or heart attack.

A long bath in hot water may cause hyperthermia (too much heat in

the body) which can be fatal. Some symptoms of hyperthermia are:

• Nausea
• Dizziness
• Fainting

If these symptoms appear while in the spa, GET OUT AT ONCE!
Cool the body at once with cold towels or a cool shower.
Call a doctor if symptoms do not go away.

Hazardous suction.
Can trap hair or
body parts, causing
severe injury
or death.

Do not block
suction.

Too much heat
can cause nausea,
dizziness,
fainting, or death.

Check temperature.
before using tub.

Содержание DURA-JET JSACL

Страница 1: ...p 293 Wright Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 www sta ritepool com Union City TN Delavan WI Mississauga...

Страница 2: ...AL CAREFULLY The Sta Rite JS Series Tub Pump Is designed to circulate hot water in spas and hot tubs Is an excellent performer durable reliable Table of Contents Safety Instructions 3 Installation 4 E...

Страница 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Relea...

Страница 4: ...r compartment Piping Use flexible or rigid PVC pipe for connections to pump Suction discharge piping gate valves will allow removal for servicing Use at least 1 1 2 IPS pipe Fittings restrict flow for...

Страница 5: ...le I Page 6 gives correct wire and circuit breaker sizes for the pump alone If other lights or appliances are also on the same circuit be sure to add their amp loads to pump amp load before figuring w...

Страница 6: ...HP Volts Amps Amp Rating 0 30 31 60 61 90 Deg C Single Speed Pumps JSACL A 1 2 115 7 0 15 14 2 0 12 3 0 10 5 5 75 JSADL 2A 3 4 115 9 0 15 14 2 0 14 2 0 10 5 5 75 JSAEL 2A 1 115 12 0 15 14 2 0 10 5 5...

Страница 7: ...ng when system is not in use Failure to do so can allow air to enter system causing pump to lose its prime Keep water temperature at 104 F 40 C or below Age or health conditions may require a lower te...

Страница 8: ...e drive ring seats and seals 6 Carefully remove four motor throughbolts from seal plate Figure 3 remove seal plate and use a screwdriver to tap ceramic seat out from the rear Figure 4 Do not damage se...

Страница 9: ...f possible store chemicals in another room Allowing pump to freeze will damage pump and void warranty Drain all water from pump and piping when expecting freezing temperatures or when storing pump for...

Страница 10: ...the low point of the spa piping to help drain spa system 6 Before restarting replace all plugs and make sure all pipe connections are tightly sealed Startup for Winterized Equipment 1 Remove any tempo...

Страница 11: ...use poor flow and poor jet action 2 Consult dealer installer or service representative C EXCESSIVE AIR IN SYSTEM PUMP LOSES PRIME 1 Make sure water level in spa is at least 2 51 mm above top of jets w...

Страница 12: ...1 JSAEFL A 11 2 AE910FLL 17301 0101 230 Volt Single Speed JSADL 230A 3 4 AS923DL C105 228PB JSAEL 230A 1 AS923EL C105 228P 230 Volt Two Speed JSAYDL 230A 3 4 AS923DL Y C105 228PB JSAYEL 230A 1 AS923EL...

Страница 13: ...13...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...pur chaser Purchaser only Sta Rite shall have the option to re pair or replace the defective product at its sole discre tion Purchasers must pay all labor and shipping charges nec essary to replace t...