Voltage:

Voltage at motor must be not more than 10% above or below motor name-
plate rated voltage or motor may overheat, causing overload tripping and re-
duced component life. If voltage is less than 90% or more than 110% of rated
voltage when motor is running at full load, consult power company.

TABLE I - RECOMMENDED WIRING DATA 50 HZ 230V. MOTORS

Dist in Ft. (M) - Service to Motor

Model

Motor

0-100

101-200

201-300

Temp.

No.

H.P.

(0-30)

(31-60)

(61-90)

Rating-°C

5JTAC-A

1/2

14 (2.0)

14 (2.0)

14 (2.0)

75

5JTAD-A

3/4 

14 (2.0)

14 (2.0)

14 (2.0)

75

TABLE II - RECOMMENDED CIRCUIT BREAKER SIZES 50 Hz 230V. MOTORS

Model

Motor

Full Load

Branch Circuit Breaker

No.

H.P.

(amps)

Rating (amps)

5JTAC-A

1/2

4.0

15

5JTAD-A

3/4

4.7

15

Содержание DURA-JET 5JTAC-A

Страница 1: ...al 800 752 0183 FAX 800 582 2217 Canada 416 629 1611 FAX 416 629 3726 International 414 728 5551 FAX 414 728 4461 TELEX ITT 4970245 Oxnard CA Orlando FL Union City TN Delavan WI Mississauga Ont Printe...

Страница 2: ...ts sole discretion Purchasers must pay all labor and shipping charges necessary to replace the product covered by this warranty Requests for warranty service must be made through the installing dealer...

Страница 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Relea...

Страница 4: ...Piping Use flexible or rigid PVC pipe for connections to pump Use at least 1 1 2 IPS pipe Fittings restrict flow for best efficiency use fewest possible fittings Unions are provided Use as follows for...

Страница 5: ...solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or condu...

Страница 6: ...tor is running at full load consult power company TABLE I RECOMMENDED WIRING DATA 50 HZ 230V MOTORS Dist in Ft M Service to Motor Model Motor 0 100 101 200 201 300 Temp No H P 0 30 31 60 61 90 Rating...

Страница 7: ...erature and gradually increase it according to your experience Keep an accurate thermometer in bath check it before getting in Do not use or allow the use of the tub by anyone using alcohol or drugs T...

Страница 8: ...unterclockwise Rotating half of seal will come off with impeller NOTICE Pump may have spacing shims inside impeller sleeve against shaft shoulder Do not lose or damage shims If impeller needs replace...

Страница 9: ...onto impeller sleeve until drive ring bottoms on impeller back shroud 4 Slip slinger over shaft remount seal plate Torque throughbolts to 25 inch lbs 29 cm kg 5 Impeller shim s if used go over threade...

Страница 10: ...use poor flow and poor jet action 2 Consult dealer installer or service representative C EXCESSIVE AIR IN SYSTEM PUMP LOSES PRIME 1 Make sure water level in spa is at least 2 51 mm above top of jets w...

Страница 11: ...260P 9 Seal 1 U9 358SS U9 358SS 10 Impeller 1 C5 228PB C5 229PA 11 O Ring 1 U9 357 U9 357 12 Front Plate 1 C1 261P C1 261P 13 Washer 1 4 Plain 6 U43 117SS U43 117SS 14 Washer 1 4 Lock 6 U43 10SS U43...

Отзывы: