READ AND FOLLOW SAFETY
INSTRUCTIONS!

This is the safety alert symbol. When you see this symbol on your system

or in this manual, look for one of the following signal words and be alert

to the potential for personal injury.

warns about hazards that 

will

cause death, serious personal 

injury, or major property damage if ignored.

warns about hazards that 

can

cause death, serious personal 

injury, or major property damage if ignored.

warns about hazards that 

will

or 

can

cause minor personal injury

or property damage if ignored.

NOTICE 

indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this manual and on equip-
ment. 

Keep safety labels in good condition; replace if missing or damaged.

Incorrectly installed or tested equipment may fail, causing
severe injury or property damage. 

Read and follow instructions in owner's manual when installing
and operating equipment. Have a trained pool professional per-

form all pressure tests.
1. Do not connect system to a high pressure or city water system.
2. Use equipment only in a pool or spa installation.
3. Install pump with at least 2 hydraulically balanced main drains equipped

with correctly installed, screw-fastened, anti-entrapment certified covers.
See Page 5.

4. Trapped air in system can cause explosion. BE SURE all air is out of system

before operating or testing equipment.

Before pressure testing, make the following safety checks:

• Check all clamps, bolts, lids, and system accessories before testing.
• Release all air in system before testing.
• Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-m) torque for testing.

Water pressure for test must be less than 25 PSI (7.5 kg/cm

2

).

• Water Temperature for test must be less than 100

o

F. (38

o

C).

• Limit test to 24 hours. After test, visually check system to be sure it is ready

for operation. Remove trap lid and retighten hand tight only.

NOTICE:

These parameters apply to Sta-Rite equipment only. For 

non-Sta-Rite equipment, consult manufacturer.

INSTALLATION

Only qualified, licensed personnel should install pump and wiring.

Pump mount must:

Be located away from corrosive or flammable chemicals.

IMPORTANT

SAFETY 

INSTRUCTIONS

Always follow basic safety pre-
cautions with this equipment, in-
cluding the following.

To reduce the risk of

injury, do not permit children to
use this product unless they are
closely supervised at all times.

This pump is for use

with permanently installed pools
and may also be used with hot
tubs and spas if so marked. Do
not use with storable pools. A
permanently installed pool is con-
structed in or on the ground or in
a building such that it cannot be
readily disassembled for storage.
A storable pool is constructed so
that it may be readily disassem-
bled for storage and reassembled
to its original integrity.

SAVE THESE 

INSTRUCTIONS

Содержание DURA-GLAS II

Страница 1: ...ght Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 www sta ritepool com Union City TN Delavan WI Mississauga Ont Murr...

Страница 2: ...oting Guide 13 Repair Parts List 14 18 Warranty 19 Max E Glas II HP 3 4 P4E6D 186L P4E62D 186L P4E6D 186LV 1 P4E6E 187L P4EA6E 186L P4E62E 187L P4E6E 187LV 1 1 2 P4E6F 188L P4EA6F 187L P4E62F 188L P4E...

Страница 3: ...sion BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing R...

Страница 4: ...g pump and piping Fire and burn hazard Modern motors run at high temperatures To reduce the risk of fire do not allow leaves debris or foreign matter to col lect around the pump motor To avoid burns w...

Страница 5: ...PUMP SUCTION REQUIREMENTS Pump suction is hazardous and can trap and drown or disem bowel bathers Do not use or operate swimming pools spas or hot tubs if a suction outlet cover is missing broken or...

Страница 6: ...ot exceed the suction fittings maxi mum designed flow rate If 100 of the pump s flow comes from the main drain system the maximum water velocity in the pump suction hydraulic system must be six feet p...

Страница 7: ...mes dangerous to pool users For size of GFCI required and test procedures for GFCI see manufac turer s instructions In case of power outage check GFCI for tripping which will prevent normal water circ...

Страница 8: ...11 5 5 8 230 460 60 3 14 2 14 2 12 3 14 2 Time delay fuses are recommended instead of standard fuses in any motor circuit Wire Size AWG mm2 Wire Size AWG mm2 Wire Size AWG mm2 Wire Size AWG mm2 Wire...

Страница 9: ...prime itself when suction and discharge valves are opened If pump is not in a flooded suction system unscrew and remove trap cover fill trap and pump with water Do not lubricate the trap cover O Ring...

Страница 10: ...ion not to break attached piping 5 Be sure motor is kept dry and covered Storage Winterizing Explosion hazard Purging the system with compressed air can cause components to explode with risk of severe...

Страница 11: ...pump is operating To avoid dangerous or fatal electrical shock hazard turn OFF power to motor before working on pump or motor Aside from lubricating trap cover O Ring no lubrication or regular mainte...

Страница 12: ...rface or seal will leak 4 Remount seal plate on motor Tighten bolts to 60 80 inch lbs 69 92 kg cm torque 5 Apply a small amount of liquid detergent to inside diameter of rotating half of seal 6 Slide...

Страница 13: ...ged follow steps 1 through 7 under Removing Old Seal Page 11 check impeller for clogging follow steps 7 through 10 under Installing New Seal Page 12 for reassembly 7 Impeller and diffuser may be worn...

Страница 14: ...14 1 1860 0795 5 6 11 12 13 16 17 18 19 15 14 10 10A 7 8 9 3 4 2 2A 20 22 23 24 21 P4E P4EA and P4E62 SERIES MAX E GLAS II POOL PUMP 3 4 through 3 HP Models...

Страница 15: ...listed except as noted Key Nos 1 Motor 10 Impeller and 11 Diffuser are listed below Key Part Part No Description Qty No 1 Motor 1 Chart at Right 2 10 32x1 2 Screw 1 U30 692SS 2A Lock Washer 1 U43 22SS...

Страница 16: ...8 Voltage Sticker 115 230 Volts U27 153 Tag CAUTION 61002 0002 Tag CAUTION WARNING Bonding C63 12 Nameplate U33 174 P4R and P4RA SERIES DURA GLAS II POOL PUMP 1 through 2 1 2 H P Models Not illustrate...

Страница 17: ...Pad 1 C104 78P 23 Motor Pad 1 C35 43 24 3 8 16 x 1 Hex Head Screw 4 U30 74SS Decal Suitable for outdoor use U27 635 Tag CAUTION 61002 0002 Tag CAUTION WARNING Bonding C63 12 Nameplate U33 174 P4R SER...

Страница 18: ...U178 920P 20 Base Screw 2 U30 918SS 21 Base Washer 2 U43 41SS 22 Base w Motor Pad 1 C104 78P 23 Motor Pad 1 C35 43 24 3 8 16 x 1 Hex Head Screw 4 U30 74SS Decal Suitable for outdoor use U27 635 Tag C...

Страница 19: ...consumer pur chaser Purchaser only Sta Rite shall have the option to re pair or replace the defective product at its sole discre tion Purchasers must pay all labor and shipping charges nec essary to...

Страница 20: ......

Отзывы: