Figure 9.
Histogram of 3500 measured distances
Note:
The mean of the measured distances, in case it equals the real distance between the sensor and the floor, is an
indication of the reliability of the setup.
In
, the mean of the measured distances from the two zones are the same and equals
the real distance between the sensor and the floor, which is 2600 mm. This indicates a reliable setup. Here, the
threshold is less than 1920 mm.
Figure 10.
Reliable setup
UM2600
Ranging on the floor to determine the threshold
UM2600
-
Rev 2
page 8/15