Issue observed:
Go command on USB-DFU interface
: The user can not use Go command through bootloader on the USB-DFU
interface.
Proposed workaround:
Instead of the USB-DFU interface, the user can use JTAG or any other communication ports supported by the
bootloader to run Go command, like USART, I
2
C, SPI or CAN FD.
6.4.2
Boot from RSS
On STM32L562E-DK, the PH3-BOOT0 is fixed to a LOW level allowing the boot from the memory address
defined by SECBOOTADD0 option byte. In order to change the boot from RSS, it is needed to set the PH3-
BOOT0 to the HIGH level by removing R32 and soldering R31, or just by applying 3V3 on PH3-BOOT0 signal
between R32 and R31. In this second case, it is not necessary to remove R32 or to add R31.
explains how to easily connect 3V3 to BOOT0.
Figure 17.
BOOT0 modification to set the HIGH level
6.5
Clock source
6.5.1
LSE clock reference
The LSE clock reference on the STM32L562QEI6QU microcontroller is done by an external crystal X2.
•
32.768 kHz crystal from NDK referenced NX2012SA
UM2617
Clock source
UM2617
-
Rev 2
page 21/61