SM CODE
VSUP_SM_0
Detailed implementation
This method must be applied to configuration registers.
Detailed information on the implementation of this method can be found in
Section 3.6.14 Extended interrupt and events controller (EXTI)
.
Error reporting
Refer to NVIC_SM_0
Fault detection time
Refer to NVIC_SM_0
Addressed fault model
Refer to NVIC_SM_0
Dependency on
Device
configuration
Refer to NVIC_SM_0
Initialization
Refer to NVIC_SM_0
Periodicity
Refer to NVIC_SM_0
Test for the diagnostic
Refer to NVIC_SM_0
Multiple-fault protection
Refer to NVIC_SM_0
Recommendations and known limitations
Refer to NVIC_SM_0
Table 35.
VSUP_SM_1
SM CODE
VSUP_SM_1
Description
Supply voltage internal monitoring (PVD)
Ownership
ST
Detailed implementation
The device features an embedded programmable voltage detector (PVD) that monitors the
V
DD
power supply and compares it to the V
PVD
threshold. An interrupt can be generated when
V
DD
drops below the V
PVD
threshold or when V
DD
is higher than the V
PVD
threshold.
Error reporting
Interrupt event generation
Fault detection time
Depends on threshold programming. Refer to functional documentation.
Addressed fault model
Permanent/transient
Dependency on
Device
configuration
None
Initialization
Protection enable by the PVDE bit and the threshold setting in the Power control register
(PWR_CR)
Periodicity
Continuous
Test for the diagnostic
Direct test procedure for PVD efficiency is not available. PVD run-time hardware failures
leading to disabling such protection fall into multiple-fault scenario, from IEC61508
perspective. Related failures are adequately mitigated by the combination of safety
mechanisms reported in this table, field
Multiple-fault protection
.
Multiple-fault protection
DIAG_SM_0: Periodic read-back of hardware diagnostics configuration registers
Recommendations and known limitations
Internal monitoring PVD has limited capability to address failures affecting STM32L4 and
Series internal voltage regulator. Refer to
Internal monitoring PVD has limited capability to address failures affecting the internal voltage
regulator. Refer to
Device
FMEA
for details.
Table 36.
VSUP_SM_2
SM CODE
VSUP_SM_2
Description
Independent watchdog
Ownership
ST
Detailed implementation
Failures in the power supplies for digital logic (core or peripherals) may lead to alteration of
Application software
timing, which can be detected by IWDG as safety mechanism introduced
to monitor
Application software
control flow. Refer to CPU_SM_1 and CPU_SM_6 for further
information.