![ST STEVAL-IHM011V1 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/st/steval-ihm011v1/steval-ihm011v1_user-manual_1355984021.webp)
UM0428
Motor control demonstration
21/27
7.5
Sensor voltage setting
W6 sets the voltage reference supplied to the Hall sensor or to the Encoder.
If W6 is set between 2-3, +5 V is supplied to the sensor.
If W6 is set between 1-2, the same voltage of the microcontroller is supplied to the sensor
(+5 or +3.3 depending W13).
For the remaining settings follow the description in
.
7.5.1 Board
connections
After the board has been configured the system can be set up as shown in
. This
configuration is called “running configuration”. The control board must be preventively
configured. (see control board user manual).
1.
Connect the insulated high voltage power supply to the J6 connector of STEVAL-
IHM011V1 (Pin 2-3).
2.
Connect the 34-pin flat cable between the two MC connectors: J4 of Control board and
J3 of power board.
3.
Connect the phases of the motor to the power board J4 connector and, if it is required,
connect the sensor signal to the Tachometer connector J2 or Hall Sensor/Encoder
connector J1 based on the sensor present inside the motor and driving strategy (see
control board user manual).
9
If it is required, connect a power supply with lower voltage output. For instance Ametek
motor requires the use of a power supply up to 30 V max.
Figure 12.
System setup for running phase